0909FCB
Part of a family of 13 devices: see the family page
Ref 0909FCB
0909FCB is an indirect flat panel x-ray detector (EU MDR Class IIa; FDA Class II) made by Rayence Co., Ltd., registered in EUDAMED on 27 Aug 2026 (Basic UDI-DI 880001861717SCCMU), cleared under FDA 510(k) K212753 on 18 Oct 2021 and listed in FDA GUDID since 29 Oct 2021 (UDI-DI 08800018600900), active as of 25 Oct 2026.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number880001861717SCCMU 08800018600900 | Date27 Aug 2026 | StatusActive |
| United States | GUDID listing GUDID | Number08800018600900 | Date29 Oct 2021 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK212753 | Date18 Oct 2021 | StatusActive |
Official records
- EUDAMED public site 880001861717SCCMU
- AccessGUDID record 08800018600900
- FDA 510(k) database K212753
From the FDA record
- Device description
- The 0909FCB flat panel detector employs a CsI:Tl scintillator for X-ray-to-light converter. Column-structurized CsI:Tl scintillator have high resolution performance due to much less light blurring, and is thus available for a longer period of time. CMOS active pixel detector makes extremely low noise level and highly sensitive performance. Due to seamless one chip CMOS, there is no data missing or artifacts. The high physical and functional performance of 0909FCB gives competitive image quality. The RAW files can be further processed as DICOM compatible image files by separate console SW for a radiographic diagnosis and analysis.
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 880001861717SCCMU registered 27 Aug 2026 Active
- FDA 510(k) K212753 decided 18 Oct 2021 Active
- FDA GUDID UDI-DI 08800018600900 listed 29 Oct 2021 Listed
Timeline
- Cleared FDA 510(k) K212753
- Listed FDA GUDID 08800018600900
- Registered EUDAMED 880001861717SCCMU
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Indirect flat panel x-ray detector
- Device name
- Medical Image Processing Unit (Flat Panel Detector)
- Model / reference
- 0909FCB
- Primary DI / UDI-DI
- 08800018600900
- Basic UDI-DI
- 880001861717SCCMU
- 510(k) Number
- FDA product code
- MQB, JAA
- EMDN code
- Z11031180 Systems for direct digital radiology (dr) - hardware accessories
- GMDN term
- Indirect flat panel x-ray detector
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1680, 892.1650
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under SYSTEMS FOR DIRECT DIGITAL RADIOLOGY (DR) - HARDWARE ACCESSORIES.
- VIVIX-M 2430D FXMD-2430DAL by VIEWORKS CO., LTD.
- Power supply unit* DR-ID 1200 MP E by FUJIFILM CORPORATION
- FDR D-EVO II Battery Charger DR1200 SE BATTERY CHARGER A E by FUJIFILM CORPORATION
- VIVIX-M 2430S FXMD-2430S by VIEWORKS CO., LTD.
- Medici DR system DR1000 by OEHM UND REHBEIN GMBH
- Mercu1717V3-VSM Digital Flat Panel Detector 03130016 by iRay Group
- PEDRA 17FC PEDRA-17FC by Radisen Co., Ltd.
- SKR 4000 ACX9 by KONICA MINOLTA, INC.
- Adapter für Miktionssitz (Töpfchenhalter) 070 by Medizintechnik St. Egidien GmbH
- PEDRA 1417MC PEDRA-1417MC by Radisen Co., Ltd.