Skip to content

10V4 Transducer 08266709

by Siemens Medical Solutions USA, Inc.

Ref 08266709Model MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_08266709

10V4 Transducer 08266709 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 7 Sep 2026 (Basic UDI-DI 0405686902400V5), cleared under FDA 510(k) K072365 on 17 Oct 2007 and listed in FDA GUDID since 24 Sep 2016 (UDI-DI 04056869002866), active as of 23 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

3 closed

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K072365

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number0405686902400V5 Basic UDI-DI 04056869002866UDI-DIDate7 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number04056869002866 UDI-DI Date24 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK072365 Date17 Oct 2007DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 0405686902400V5 registered 7 Sep 2026 Active
  • FDA 510(k) K072365 decided 17 Oct 2007 Active
  • FDA GUDID UDI-DI 04056869002866 listed 24 Sep 2016 Listed

Recalls

3 recalls · FDA

  • 2 recalls, same reason

    • Terminated Z-0826-2011 FDA Unclassified (pre-2012) initiated 29 Sep 2010 on shared 510(k) K072365
    • Terminated Z-0827-2011 FDA Unclassified (pre-2012) initiated 29 Sep 2010 on shared 510(k) K072365

    There is the possibility of a short occurring in the transducer which could cause focal heating on the probe face.

    • Terminated Z-2149-2011 FDA Unclassified (pre-2012) initiated 10 Jul 2009 on shared 510(k) K072365

    Burn risk-- due to coolant leaks, patients may suffer burns or blisters due to increased temperature.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K072365
  2. Recall initiated FDA recalls Z-2149-2011
  3. Recall initiated FDA recalls Z-0826-2011
  4. Recall initiated FDA recalls Z-0827-2011
  5. Listed FDA GUDID 04056869002866
  6. Registered EUDAMED 0405686902400V5

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
10V4 Transducer
Generic name
Extracorporeal ultrasound imaging transducer, hand-held
Device name
MDR_07_IIA_IQH_BTS Lb A_ACDV_10V4_08266709
Model / reference
08266709, MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_08266709
Primary DI / UDI-DI
04056869002866
Basic UDI-DI
0405686902400V5
510(k) Number
FDA product code
ITX
EMDN code
Z110402010301 Transcutaneous ultrasound sector probes (phased array), two–dimensional
GMDN term
Extracorporeal ultrasound imaging transducer, hand-held
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1570
EU registration type
Standard device
EU market of registration
Germany
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under TRANSCUTANEOUS ULTRASOUND SECTOR PROBES (PHASED ARRAY), TWO–DIMENSIONAL.

Other devices from Siemens Medical Solutions USA, Inc.

See all devices from Siemens Medical Solutions USA, Inc. →

Properties

  • Serial number
Other properties (24, all answered No)