10V4 Transducer 11319697
by Siemens Medical Solutions USA, Inc.
Ref 11319697Model MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_11319697
10V4 Transducer 11319697 is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, ultrasonic, diagnostic) made by Siemens Medical Solutions USA, Inc., registered in EUDAMED on 7 Sep 2026 (Basic UDI-DI 0405686902421VD), cleared under FDA 510(k) K201130 on 26 May 2020 (1 earlier submission) and listed in FDA GUDID since 20 Feb 2018 (UDI-DI 04056869051925), active as of 23 Oct 2026.
Active
Valid until
No date given
FDA recalls
3 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0405686902421VD 04056869051925 | Date7 Sep 2026 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK201130 | Date26 May 2020 | StatusActive |
| United States | GUDID listing GUDID | Number04056869051925 | Date20 Feb 2018 | StatusListed |
Official records
- EUDAMED public site 0405686902421VD
- AccessGUDID record 04056869051925
- FDA 510(k) database K201130
- FDA 510(k) database K180039
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 0405686902421VD registered 7 Sep 2026 Active
- FDA 510(k) K201130 decided 26 May 2020 Active
- FDA GUDID UDI-DI 04056869051925 listed 20 Feb 2018 Listed
Recalls
-
- Ongoing Z-3215-2024
If ultrasound systems with software, are changed from factory default to : 1) Milliliters per second (ml/sec, mL/sec) or 2) Milliliters per minute (ml/min, mL/min); then systems will perform incorrect unit conversion of liters to milliliters using multiplier 100 instead of 1000, resulting values 10x smaller than actual, which could contribute misdiagnosis or negatively influence patient management
-
- Ongoing Z-1599-2024
On ultrasound systems, when Cardiac DICOM SR feature is configured to display either minimum or maximum measured value, and multiple cardiac region measurements are made, and results are exported into the SR feature, then The SR viewer will display the LAST measured value, not min or max, which could contribute to patient condition misdiagnosis or negatively influence patient management decisions.
-
- Ongoing Z-0748-2022
The clip store function in the ultrasound imaging system does not work when the system has a disk full error. This could cause a delay in treatment if the ultrasound system is unable to save clips as study documentation during a high risk procedure, such as a stress echo exam.
-
- Terminated Z-2471-2021
Due to intermittent failures of the power supply in the ultrasound system which renders it inoperable.
Timeline
- Cleared FDA 510(k) K180039
- Listed FDA GUDID 04056869051925
- Cleared FDA 510(k) K201130
- Recall initiated FDA recalls Z-2471-2021
- Recall initiated FDA recalls Z-0748-2022
- Recall initiated FDA recalls Z-1599-2024
- Recall initiated FDA recalls Z-3215-2024
- Registered EUDAMED 0405686902421VD
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 10V4 Transducer
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- MDR_07_IIA_IQH_BTS Lb A_ACDV_10V4_11319697
- Model / reference
- 11319697, MDR_07_IIA_IQH_BTS LB A_ACDV_10V4_11319697
- Primary DI / UDI-DI
- 04056869051925
- Basic UDI-DI
- 0405686902421VD
- FDA product code
- ITX
- EMDN code
- Z110402010301 Transcutaneous ultrasound sector probes (phased array), two–dimensional
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under TRANSCUTANEOUS ULTRASOUND SECTOR PROBES (PHASED ARRAY), TWO–DIMENSIONAL.
- P10xp/8-4 MHz P17780-21A by Fujifilm Sonosite, Inc.
- PR54 by SONOSCANNER
- PA121E 9600151000 by Esaote S.p.A.
- HUMANSCAN 5438302-2 500395 by Humanscan Company, Ltd.
- P10xp/8-4 MHz P17780-20A by Fujifilm Sonosite, Inc.
- SP3630 122001400 by Esaote S.p.A.
- HUMANSCAN GE-R3MIX 500395 by Humanscan Company, Ltd.
- 6Sc-D H46462LS by GE Healthcare Japan Corporation
- 5P1 Transducer 9077 by BK MEDICAL APS
- S11 04573596212233 by FUJIFILM CORPORATION