Ref 1212FCA

1212FCA is an indirect flat panel x-ray detector (EU MDR Class IIa; FDA Class II; FDA product code MQB, Solid State X-Ray Imager (Flat Panel/Digital Imager)) made by Rayence Co., Ltd., registered in EUDAMED on 27 Aug 2026 (Basic UDI-DI 880001861717SCCMU), cleared under FDA 510(k) K202722 on 26 Oct 2020 and listed in FDA GUDID since 4 Nov 2020 (UDI-DI 08800018600641), active as of 25 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE MDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 25 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K202722

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 25 Oct 2026.

Regulatory status

as of registry sync 25 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number880001861717SCCMU Basic UDI-DI 08800018600641UDI-DIDate27 Aug 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number08800018600641 UDI-DI Date4 Nov 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK202722 Date26 Oct 2020DecidedStatusActive

Official records

From the FDA record

Device description
1212FCA is a digital solid state X-ray detector that is based on flat-panel technology. This radiographic image detector and processing unit consists of a scintillator coupled to an IGZO TFT sensor. This device needs to be integrated with a radiographic imaging system. It can be utilized to capture and digitalize X-ray images for radiographic diagnosis. The RAW files can be further processed as DICOM compatible image files by separate console SW for a radiographic diagnosis and analysis. The subject detectors are not wireless, but they are connected to a viewing station by ethernet connection.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 25 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 880001861717SCCMU registered 27 Aug 2026 Active
  • FDA 510(k) K202722 decided 26 Oct 2020 Active
  • FDA GUDID UDI-DI 08800018600641 listed 4 Nov 2020 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K202722
  2. Listed FDA GUDID 08800018600641
  3. Registered EUDAMED 880001861717SCCMU

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Generic name
Indirect flat panel x-ray detector
Device name
Medical Image Processing Unit (Flat Panel Detector)
Model / reference
1212FCA
Primary DI / UDI-DI
08800018600641
Basic UDI-DI
880001861717SCCMU
510(k) Number
FDA product code
MQB
EMDN code
Z11031180 Systems for direct digital radiology (dr) - hardware accessories
GMDN term
Indirect flat panel x-ray detector
Device class
Class IIa EUDAMED
Class II GUDID
Regulation number
892.1680
EU registration type
Standard device
EU market of registration
France
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIa
GUDID
Class II

Device class is stated on each registry's own scale: Class IIa in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under SYSTEMS FOR DIRECT DIGITAL RADIOLOGY (DR) - HARDWARE ACCESSORIES.

Other devices from Rayence Co., Ltd.

See all devices from Rayence Co., Ltd. →

Properties

  • Prescription use
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)