12l-RS
by GE Healthcare Japan Corporation
Ref H40402LYModel 5141337
12l-RS (H40402LY) is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II) made by GE Healthcare Japan Corporation, registered in EUDAMED on 30 Apr 2025 (Basic UDI-DI 8406821BUG00234H7), cleared under FDA 510(k) K160162 on 26 Apr 2016 and listed in FDA GUDID since 15 Jul 2016 (UDI-DI 00840682106870), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number8406821BUG00234H7 00840682106870 | Date30 Apr 2025 | StatusActive |
| United States | GUDID listing GUDID | Number00840682106870 | Date15 Jul 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK160162 | Date26 Apr 2016 | StatusActive |
Official records
- EUDAMED public site 8406821BUG00234H7
- AccessGUDID record 00840682106870
- FDA 510(k) database K160162
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- EUDAMED Basic UDI-DI 8406821BUG00234H7 registered 30 Apr 2025 Active
- FDA 510(k) K160162 decided 26 Apr 2016 Active
- FDA GUDID UDI-DI 00840682106870 listed 15 Jul 2016 Listed
Recalls
-
- Ongoing Z-0865-2024
GE HealthCare has become aware of an issue with certain IC9-RS ultrasound probes (see Affected Products List) that can result in a double image artifact creating a ghost image with realistic features. An unrecognized artifact may lead to misdiagnosis.
Timeline
- Cleared FDA 510(k) K160162
- Listed FDA GUDID 00840682106870
- Recall initiated FDA recalls Z-0865-2024
- Registered EUDAMED 8406821BUG00234H7
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Model / reference
- 5141337 EUDAMEDH40402LY EUDAMED12L-RS GUDID
- Primary DI / UDI-DI
- 00840682106870
- Basic UDI-DI
- 8406821BUG00234H7
- Direct marketing DI
- 00840682106870
- 510(k) Number
- FDA product code
- IYO, IYN, ITX
- EMDN code
- Z110402010101 Two–dimensional linear–array transcutaneous ultrasound probes
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1560, 892.1550, 892.1570
- EU registration type
- Standard device
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | 5141337 H40402LY | 12L-RS |
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- JP-MF-000009291
- Authorised representative
- GE Medical Systems SCS FR-AR-000000344
Similar devices in this category
Other devices filed under TWO–DIMENSIONAL LINEAR–ARRAY TRANSCUTANEOUS ULTRASOUND PROBES.
- L55 04573596212165 by FUJIFILM CORPORATION
- IOT342 121201600 by Esaote S.p.A.
- IL 4-13 120000027 by Esaote S.p.A.
- VF10-5 Transducer 10136142 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- 14L4a Transducer 11711446 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- SLAx/13-6 MHz P07699-71 by Fujifilm Sonosite, Inc.
- Vscan Air CL GP000160 by Ge Vingmed Ultrasound
- ML4-20VN-D 5838851 by GE Parallel Design, Inc.
- HFL50xp/15-6 MHz P14567-22A by Fujifilm Sonosite, Inc.
- Linear Probe L14-4 A8J9 by KONICA MINOLTA, INC.