Skip to content

1688 Pendulum 4K Camera Head with Integrated Coupler, 1688 4K Camera Control Unit

by Stryker

510(k) K200310

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Special NumberK200310 Date6 Mar 2020ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
1688 Pendulum 4K Camera Head with Integrated Coupler, 1688 4K Camera Control Unit with Advanced Imaging Modality
510(k) Number
FDA Product Code
GCJ
Device Class
Class II
Regulation
21 CFR Part 876.1500
Advisory Committee
Gastroenterology, Urology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The 1688 Pendulum 4K Camera Head with Integrated Coupler and 1688 4K Camera Control Unit form a high-definition endoscopic imaging system designed for advanced visualisation in minimally invasive procedures. This device combines a lightweight camera head with a central control unit, delivering 4K resolution across five imaging modalities, including visible and infrared spectrums. The camera head features an automatic image flip function to maintain orientation during use. Intended for use in urology and gastroenterology, it provides enhanced clarity for diagnostic and surgical applications.

The system is supplied as a reusable medical device, intended for use in controlled clinical environments such as operating rooms and endoscopy suites. The camera head and control unit are designed for integration with compatible endoscopes, ensuring compatibility with MRI-safe procedures where applicable. Storage and handling follow standard sterile or non-sterile medical device protocols, depending on procedural requirements. Authorised for commercial distribution in the United States under an FDA 510(k) clearance (K200310), this device adheres to regulatory standards for endoscopic imaging systems.

Other devices from Stryker Corp.

See all devices from Stryker Corp. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What procedures is the 1688 4K Camera System designed for?

    This system is specifically engineered for advanced visualisation in minimally invasive procedures within urology and gastroenterology. Its 4K resolution and five imaging modalities—including visible and infrared spectrums—provide enhanced clarity for both diagnostic evaluations and surgical interventions, ensuring better precision in these specialties.

  • Is the 1688 4K Camera System reusable or single-use?

    The 1688 4K Camera System is designed as a reusable medical device. It is intended for use in controlled clinical environments like operating rooms and endoscopy suites, where proper cleaning, disinfection, and maintenance protocols are followed to ensure safety and performance across multiple procedures.

  • What imaging modalities does the system support?

    The system supports five imaging modalities, including standard visible light and infrared spectrum imaging. This versatility allows clinicians to adapt the camera to different procedural needs, such as enhanced tissue visualization or thermal imaging, depending on the clinical context.

  • Can the 1688 4K Camera System be used with MRI-safe endoscopes?

    Yes, the camera head and control unit are designed for integration with compatible MRI-safe endoscopes where applicable. This ensures flexibility for procedures requiring MRI compatibility, though the specific endoscope must meet MRI safety standards for the system to function safely in such environments.

  • How should the 1688 4K Camera System be stored and handled?

    Storage and handling follow standard protocols for reusable medical devices, depending on whether the system is used in sterile or non-sterile procedures. The camera head and control unit should be cleaned, disinfected, and stored in a clean, dry environment to maintain functionality and prevent contamination between uses.