Skip to content

2.0mm System Plate 01-9207

by Biomet Microfixation, Inc

Ref 01-9207

2.0mm System Plate 01-9207 is a craniofacial fixation plate (EU MDD Class IIb; FDA Class II) made by Biomet Microfixation, Inc, registered in EUDAMED on 23 Oct 2026 (Basic UDI-DI B-00841036017064), cleared under FDA 510(k) K121624 on 12 Oct 2012 (2 earlier submissions) and listed in FDA GUDID since 11 Oct 2015 (UDI-DI 00841036017064), active as of 7 Nov 2026. 3 FDA recalls are linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None ongoing

4 closed

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 7 Nov 2026.

Regulatory status

as of registry sync 7 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-00841036017064 Basic UDI-DI 00841036017064UDI-DIDate23 Oct 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00841036017064 UDI-DI Date11 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK121624 Date12 Oct 2012DecidedStatusActive

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 7 Nov 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-00841036017064 registered 23 Oct 2026 Active
  • FDA 510(k) K121624 decided 12 Oct 2012 Active· +2 more in the status table
  • FDA GUDID UDI-DI 00841036017064 listed 11 Oct 2015 Listed

Recalls

4 recalls · FDA

    • Terminated Z-1220-2017 FDA Class II initiated 10 Jan 2017 on shared 510(k) K121589

    The identification of the devices was non-conforming with off-centered slots and the no-go gage starting in the pilot hole.

  • 2 recalls, same reason

    • Terminated Z-0137-2016 FDA Class II initiated 6 Aug 2015
    • Terminated Z-0136-2016 FDA Class II initiated 6 Aug 2015

    The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force.

    • Terminated Z-0108-2011 FDA Unclassified (pre-2012) initiated 31 Aug 2010

    Mislabeled size: The 2.0/1.0 4 hole long plate, Lot 120150 is labeled as 01-9205 (2.0/1.0 4 Hole Long Plate), however, the package contains a 01-9204 (2.0/1.0 4 Hole Regular Plate).

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

9 dated events

  1. Cleared FDA 510(k) K854886
  2. Recall initiated FDA recalls Z-0108-2011
  3. Cleared FDA 510(k) K121589
  4. Cleared FDA 510(k) K121624
  5. Recall initiated FDA recalls Z-0137-2016
  6. Recall initiated FDA recalls Z-0136-2016
  7. Listed FDA GUDID 00841036017064
  8. Recall initiated FDA recalls Z-1220-2017
  9. Registered EUDAMED B-00841036017064

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
"""2.0mm"" System Plate" EUDAMED
"2.0mm" System Plate GUDID
Generic name
Craniofacial fixation plate, non-bioabsorbable, non-customized
Model / Ref / Catalog
01-9207
Primary DI / UDI-DI
00841036017064
Basic UDI-DI
B-00841036017064
FDA product code
GXR, GWO, HBW, JEY
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Craniofacial fixation plate, non-bioabsorbable, non-customized
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
882.5250, 882.5320, 882.5360, 872.4760
EU registration type
Legacy device (under a directive)
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from Biomet Microfixation, Inc

See all devices from Biomet Microfixation, Inc →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)