Skip to content

21122-8

by I.T.S. GmbH

Ref 21122-8

21122-8 is an orthopaedic fixation plate (EU MDD Class IIb; FDA Class II; FDA product code HRS, Plate, Fixation, Bone) made by I.T.S. GmbH, registered in EUDAMED on 15 Dec 2025 (Basic UDI-DI B-09120034305207), cleared under FDA 510(k) K050852 on 22 Jun 2005 and listed in FDA GUDID since 6 Sep 2016 (UDI-DI 09120034305207), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K050852

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDD EUDAMED NumberB-09120034305207 Basic UDI-DI 09120034305207UDI-DIDate15 Dec 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number09120034305207 UDI-DI Date6 Sep 2016ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK050852 Date22 Jun 2005DecidedStatusActive

Official records

From the FDA record

Device description
Clavicle Plate 3.5mm, 8-Hole
MRI safety
MR Conditional
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI B-09120034305207 registered 15 Dec 2025 Active
  • FDA 510(k) K050852 decided 22 Jun 2005 Active
  • FDA GUDID UDI-DI 09120034305207 listed 6 Sep 2016 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1593-2026 FDA Class II initiated 23 Jan 2026

    Updated MRI safety testing demonstrates higher RF-induced temperature increases under certain MRI conditions than previously reflected in the Instructions for Use (IFU).

Timeline

4 dated events

  1. Cleared FDA 510(k) K050852
  2. Listed FDA GUDID 09120034305207
  3. Registered EUDAMED B-09120034305207
  4. Recall initiated FDA recalls Z-1593-2026

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Clavicle Plate 3.5mm
Generic name
Orthopaedic fixation plate, non-bioabsorbable
Model / Ref / Catalog
21122-8
Primary DI / UDI-DI
09120034305207
Basic UDI-DI
B-09120034305207
510(k) Number
FDA product code
HRS
EMDN code
P09120503 Osteosynthesis screw-plate systems
GMDN term
Orthopaedic fixation plate, non-bioabsorbable
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
888.3030
EU registration type
Legacy device (under a directive)
EU market of registration
Austria
GUDID distribution status
In Commercial Distribution
Sterilisation method
Moist Heat or Steam Sterilization
MRI safety
MR Conditional

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Manufacturer details

EUDAMED SRN
AT-MF-000000249

Similar devices in this category

Other devices filed under OSTEOSYNTHESIS SCREW-PLATE SYSTEMS.

Other devices from I.T.S. GmbH

See all devices from I.T.S. GmbH →

Properties

  • Sterilise before use
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
Other properties (20, all answered No)