← Back to catalogue

28mm Polarcup Unipolar Conversion +8mm

EUDAMEDFDA UDI

Class IIa (EU MDR)

Ref 35130045

by Enztec Limited

Identity

Trade Name
28mm Polarcup Unipolar Conversion +8mm EUDAMEDFDA UDI
Generic Name
Acetabulum prosthesis trial, prefabricated, reusable FDA UDI
Device Name
Trials EUDAMED
A surgical instrument representative of the definitive implant, intended to be used during an orthopaedic surgical procedure to assist in the selection of the correct size and/or position of the definitive implant. FDA UDI
Model / Reference
35130045 EUDAMEDFDA UDI
Description
A surgical instrument representative of the definitive implant, intended to be used during an orthopaedic surgical procedure to assist in the selection of the correct size and/or position of the definitive implant. FDA UDI

Identifiers

Catalog Number
35130045 FDA UDI
Primary DI / UDI-DI
09421028112895 EUDAMEDFDA UDI
Basic UDI-DI
942102811GMN00262B EUDAMED
Direct Marketing DI
09421028112895 EUDAMED
FDA Product Code
HWT FDA UDI
EMDN Code
L0999 ORTHOPAEDIC AND TRAUMATOLOGICAL SURGERY INSTRUMENTS, REUSABLE - OTHER EUDAMED
GMDN Term
Acetabulum prosthesis trial, prefabricated, reusable FDA UDI

Classification

Device Class
Class IIa EUDAMED
Class I FDA UDI
Regulation Number
888.4800 FDA UDI
Market of Registration
Netherlands EUDAMED
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

EUDAMEDFDA UDI

Single Use

No

FDA UDI

Implantable

No

EUDAMEDFDA UDI

Reusable

Yes

EUDAMED

Contains Latex

No

EUDAMEDFDA UDI

Reprocessed

No

EUDAMED

CMR Substance

No

EUDAMED

Human-derived

No

EUDAMED

Human Tissues

No

EUDAMED

Animal Tissues

No

EUDAMED

Endocrine Disruptor

No

EUDAMED

Administering Medicine

No

EUDAMED

Measuring Function

No

EUDAMED

Incorporates Medicinal Product

No

EUDAMED

Prescription Use

No

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

Yes

FDA UDI

Lot / Batch Number

Yes

FDA UDI

Serial Number

No

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

No

FDA UDI
Sterilization Method
Moist Heat or Steam Sterilization FDA UDI

28mm Polarcup Unipolar Conversion +8mm by Enztec Limited — Class IIa — MDR, FDA UDI — listed in EUDAMED, FDA GUDID — regulatory data on deviCERTS

Authorization Coverage (2 countries)

Regulatory Authorizations

European Union Active

CE/MDR

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Manufacturer
Enztec Limited
EUDAMED SRN
NZ-MF-000002264
Authorised Representative
Advena Limited MT-AR-000000234

Sources (2)

  • EUDAMED c6a3ea80-f26a-4738-8f47-05e682b53ce1 61 fields · synced Jun 18, 2026
  • FDA UDI 6eb49fee-6820-4f8f-9eba-287d47cc27ca 34 fields · synced May 30, 2026