2CWL
Part of a family of 11 devices: see the family page
Ref 120000106
2CWL (120000106) is an extracorporeal ultrasound imaging transducer (EU MDR Class IIa; FDA Class II; FDA product code ITX, Transducer, Ultrasonic, Diagnostic) made by Esaote S.p.A., cleared under FDA 510(k) K230179 on 29 Nov 2023, registered in EUDAMED on 23 Nov 2022 (Basic UDI-DI 805630445ESA.PR0000011.SQ) and listed in FDA GUDID since 7 Jul 2025 (UDI-DI 08056304455062), active as of 22 Oct 2026. One FDA recall is linked to it.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing GUDID | Number08056304455062 | Date7 Jul 2025 | StatusListed |
| United States | FDA 510(k) GUDID | NumberK230179 | Date29 Nov 2023 | StatusActive |
| European Union | CE/MDR EUDAMED | Number805630445ESA.PR0000011.SQ 08056304455062 | Date23 Nov 2022 | StatusActive |
Official records
- EUDAMED public site 805630445ESA.PR0000011.SQ
- AccessGUDID record 08056304455062
- FDA 510(k) database K230179
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- Labelled as not made with natural rubber latex
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K230179 decided 29 Nov 2023 Active
- EUDAMED Basic UDI-DI 805630445ESA.PR0000011.SQ registered 23 Nov 2022 Active
- FDA GUDID UDI-DI 08056304455062 listed 7 Jul 2025 Listed
Recalls
-
- Completed Z-1490-2026
A potential weakness has been identified in the probe body, so that, in a specific production batch, liquid may leak from the terminal part of the casing near the cable.
Timeline
- Registered EUDAMED 805630445ESA.PR0000011.SQ
- Cleared FDA 510(k) K230179
- Recall initiated FDA recalls Z-1490-2026
- Listed FDA GUDID 08056304455062
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Extracorporeal ultrasound imaging transducer, hand-held
- Device name
- Phased Array / Low Frequency
- Model / reference
- 120000106
- Primary DI / UDI-DI
- 08056304455062
- Basic UDI-DI
- 805630445ESA.PR0000011.SQ
- FDA product code
- ITX
- EMDN code
- Z110402010302 Transcutaneous ultrasound sector probes (phased array), multidimensional
- GMDN term
- Extracorporeal ultrasound imaging transducer, hand-held
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 892.1570
- EU registration type
- Standard device
- EU market of registration
- Italy
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- IT-MF-000019024
Similar devices in this category
Other devices filed under TRANSCUTANEOUS ULTRASOUND SECTOR PROBES (PHASED ARRAY).
- ML4-20-D 5838850 by GE Parallel Design, Inc.
- 5Z1 Transducer 11290766 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- 4Z1c Transducer 10789391 by SIEMENS MEDICAL SOLUTIONS USA, INC.
- ML4-20VN-D 5838851 by GE Parallel Design, Inc.
- D2XP/2 MHz P19784-21 by Fujifilm Sonosite, Inc.
- HUMANSCAN 5327196-2 500395 by Humanscan Company, Ltd.
- S42 04573596212363 by FUJIFILM CORPORATION
- S121 04573596212257 by FUJIFILM CORPORATION
- rP19xp/5-1 MH P22557-11 by Fujifilm Sonosite, Inc.
- Sector Probe S4-2 A7CA by KONICA MINOLTA, INC.