Skip to content

3mensio Workstation 10.7

by Pie Medical Imaging B.V.

Ref 10.7

3mensio Workstation 10.7 is a medical device (EU MDR Class IIb; FDA Class II; FDA product code LLZ, System, Image Processing, Radiological) made by Pie Medical Imaging B.V., registered in EUDAMED on 15 Jun 2026 (Basic UDI-DI 8056304453mensioWSZ9), cleared under FDA 510(k) K250330 on 3 Nov 2025 (1 earlier submission) and listed in FDA GUDID since 29 Apr 2025 (UDI-DI 08056304455925), active as of 24 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE MDR CE MDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

2 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number8056304453mensioWSZ9 Basic UDI-DI 08056304455925UDI-DIDate15 Jun 2026RegisteredStatusActive
European UnionCE/MDD EUDAMED Number8056304453mensioWSZ9 Basic UDI-DI 08056304455925UDI-DIDate15 Jun 2026RegisteredStatusActive
United StatesFDA 510(k) GUDID from GUDID NumberK250330 Date3 Nov 2025IssuedStatusActive
United StatesGUDID listing GUDID Number08056304455925 UDI-DI Date29 Apr 2025ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 8056304453mensioWSZ9 registered 15 Jun 2026 Active· +1 more in the status table
  • FDA 510(k) K250330 decided 3 Nov 2025 Active· +1 more in the status table
  • FDA GUDID UDI-DI 08056304455925 listed 29 Apr 2025 Listed

Recalls

2 recalls · 2 ongoing · FDA

    • Ongoing Z-2767-2026 FDA Class II initiated 7 May 2026 on shared 510(k) K250330

    User measurement value reported by diagnostic bioimaging software intended to measure/visualize cardiovascular structures may be larger (0.8% to 34.4%) than the actual anatomical dimension, if all the following occur: affected software is used, and the user has access only to 3D Echo OR Mitral 3D Echo, and the dataset being analyzed is a Philips 3D echo dataset containing Color Doppler information

    • Ongoing Z-2297-2025 FDA Class II initiated 14 Jul 2025

    When fenestrated analysis with clock measurements is started in diagnostic bioimaging software (intended to measure/visualize cardiovascular structures) and the 12h position of a single clock is changed, other clock measurements are not updated relative to the new 12h position which may cause stent graft fenestrations at incorrect position, which may lead to blood flow disruption and tissue damage

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

6 dated events

  1. Cleared FDA 510(k) K153736
  2. Listed FDA GUDID 08056304455925
  3. Recall initiated FDA recalls Z-2297-2025
  4. Cleared FDA 510(k) K250330
  5. Recall initiated FDA recalls Z-2767-2026
  6. Registered EUDAMED 8056304453mensioWSZ9

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR, CE/MDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
3mensio Workstation
Generic name
Radiology DICOM image processing application software
Model / reference
10.7
Primary DI / UDI-DI
08056304455925
Basic UDI-DI
8056304453mensioWSZ9
Direct marketing DI
08056304455925
510(k) Number
FDA product code
LLZ
EMDN code
Z11039082 Various radiodiagnostic and interventional instruments - software accessories
GMDN term
Radiology DICOM image processing application software
Device class
Class IIb EUDAMED
Class II GUDID
Regulation number
892.2050
Special device type
Software
EU registration type
Standard device
EU market of registration
Netherlands
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class IIb
GUDID
Class II

Device class is stated on each registry's own scale: Class IIb in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under VARIOUS RADIODIAGNOSTIC AND INTERVENTIONAL INSTRUMENTS - SOFTWARE ACCESSORIES.

Other devices from Pie Medical Imaging B.V.

See all devices from Pie Medical Imaging B.V. →

Properties

  • Measuring function
  • Prescription use
  • Manufacturing date
Other properties (22, all answered No)