Skip to content

40 cc Grande

by Boston Scientific

510(k) K974247

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 6 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK974247 Date10 Feb 1998ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 6 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
DSP
FDA applicant
Boston Scientific Corp
Device class
Class II
Regulation
21 CFR Part 870.3535
Advisory committee
Cardiovascular
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The 40 cc Grande is an intra-aortic balloon system designed for mechanical circulatory support. It features a polyurethane-coated nylon shaft with a symmetrical polyurethane balloon at the distal end, coated with a thin layer of silicone fluid for lubricity and performance. The device is intended for temporary hemodynamic augmentation in patients with acute cardiac conditions.

This device is supplied as a single-use, sterile system and is regulated under FDA 510(k) clearance (K974247) as a Class II medical device (product code DSP). It is intended for use in controlled clinical settings, such as cardiac catheterization labs, and requires proper storage under manufacturer-recommended conditions to maintain sterility and functionality. The system includes a central lumen for inflation/deflation control and is compatible with standard intra-aortic balloon pump protocols.

Other devices from Boston Scientific

See all devices from Boston Scientific →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical scenarios is the 40 cc Grande intra-aortic balloon system primarily used for?

    The 40 cc Grande is designed for temporary hemodynamic augmentation in patients experiencing acute cardiac conditions, such as severe heart failure or cardiogenic shock, where mechanical circulatory support is required to stabilize the patient’s circulation. It is intended for use in controlled settings like cardiac catheterization labs to assist with short-term cardiac function during critical interventions.

  • Is the 40 cc Grande system single-use or reusable, and how does this affect its handling?

    The 40 cc Grande is explicitly labeled as a single-use device, meaning it is intended for one-time use only. This design ensures sterility and safety, as reuse could compromise integrity and introduce infection risks. After use, the system must be discarded, and a new sterile unit must be prepared for subsequent procedures.

  • What storage conditions are required to maintain the device’s sterility and functionality?

    The manufacturer recommends storing the 40 cc Grande under controlled conditions to preserve sterility and functionality. While specific details like temperature or humidity aren’t provided, standard sterile medical device storage practices—such as keeping it in its original packaging, away from direct sunlight or extreme temperatures—should be followed. Always refer to the included instructions for precise storage guidelines.

  • What materials is the 40 cc Grande constructed from, and how does this impact its performance?

    The device features a polyurethane-coated nylon shaft with a symmetrical polyurethane balloon at the distal end. The balloon is further coated with a thin layer of silicone fluid to enhance lubricity and performance during inflation/deflation cycles. These materials contribute to durability, flexibility, and compatibility with standard intra-aortic balloon pump protocols, ensuring reliable hemodynamic support.

  • How is the 40 cc Grande’s inflation/deflation controlled, and what compatibility considerations should clinicians keep in mind?

    The system includes a central lumen specifically designed for inflation and deflation control, allowing precise regulation of the balloon’s cycle. It is engineered to be compatible with standard intra-aortic balloon pump protocols, meaning it can integrate seamlessly with existing clinical systems. Clinicians should verify compatibility with their specific pump equipment before use to ensure optimal performance and safety.