4K UHD Endoscopy Camera System (KMS-4K-2088, KMS-4K-2188, KMS-4K-2288)
by KMS Medical Technology Co., Ltd
510(k) K252858Ref KMS4KModel KMS-4K-2088, KMS-4K-2188, KMS-4K-2288
Active
Valid until
Not listed
FDA recalls
None foundTrust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE 510(k) | NumberK252858 | Date30 Apr 2026 | StatusActive |
| European Union | CE/MDR EUDAMED | Number697639493KMS4KCAMPM 16976394931170 | Date2 Apr 2026 | StatusActive |
Certificates
EUDAMED lists no certificate for this device's Basic UDI-DI.
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade Name
- 4K UHD Endoscopy Camera System
- Model / Reference
- KMS-4K-2088, KMS-4K-2188, KMS-4K-2288, KMS4K
- FDA applicant
- Kms Medical Technology Co., Ltd.
- Primary DI / UDI-DI
- 16976394931170
- Basic UDI-DI
- 697639493KMS4KCAMPM
- Direct Marketing DI
- 16976394931170
- 510(k) Number
- FDA Product Code
- GCJ
- EMDN Code
- Z12020401 Integrated systems for the acquisition and management of endoscopic and minimally invasive surgery images
- Device Class
- Class I EUDAMEDClass II 510(k)
- Regulation
- 21 CFR Part 876.1500
- EU market of registration
- Portugal
- Advisory Committee
- Gastroenterology, Urology
- FDA Decision
- SESE Substantially Equivalent
Truth per registry
| Field | EUDAMED | 510(k) |
|---|---|---|
| Device Class | Class I | Class II |
Overview
AI-generated summary, 18 Sep 2026
The 4K UHD Endoscopy Camera System (KMS-4K-2088, KMS-4K-2188, KMS-4K-2288) is a high-resolution imaging device designed for endoscopic procedures. It captures optical signals from an endoscope, converts them into electronic signals via a CMOS image sensor in the camera head, and transmits 4K Ultra High Definition (3840x2160) video for real-time visualization.
The system is intended for use in professional healthcare settings by trained medical personnel. It includes a Camera Control Unit (CCU) for processing, recording, and outputting video via DVI, 3G-SDI, or HDMI interfaces. The device holds FDA 510(k) clearance and MDR authorization, classified under product code GCJ for general and plastic surgery applications.
Properties
Other properties (13)
- Sterile: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Measuring Function: No
- Incorporates Medicinal Product: No