5x95 Optical Trocar
Ref EO0509505
5x95 Optical Trocar (EO0509505) is a laparoscopic trocar blade (EU MDD Class IIa; FDA Class II; FDA product code GCJ, Laparoscope, General & Plastic Surgery) made by Surgical Innovations Ltd., registered in EUDAMED on 8 Jan 2023 (Basic UDI-DI B-05051986013411), cleared under FDA 510(k) K210495 on 18 Jun 2021 and listed in FDA GUDID since 9 May 2022 (UDI-DI 05051986013411), active as of 24 Oct 2026. 2 FDA recalls are linked to it.
Active
CE MDD 510(k)
Valid until
No date given
FDA recalls
2 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-05051986013411 05051986013411 | Date8 Jan 2023 | StatusActive |
| United States | GUDID listing GUDID | Number05051986013411 | Date9 May 2022 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK210495 | Date18 Jun 2021 | StatusActive |
Official records
- EUDAMED public site B-05051986013411
- AccessGUDID record 05051986013411
- FDA 510(k) database K210495
From the FDA record
- Device description
- 5x 95 Optical Trocar
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI B-05051986013411 registered 8 Jan 2023 Active
- FDA 510(k) K210495 decided 18 Jun 2021 Active
- FDA GUDID UDI-DI 05051986013411 listed 9 May 2022 Listed
Recalls
-
- Ongoing Z-1602-2023
- Ongoing Z-1601-2023
Optical Trocars sterility assurance can not be guaranteed
Timeline
- Cleared FDA 510(k) K210495
- Listed FDA GUDID 05051986013411
- Registered EUDAMED B-05051986013411
- Recall initiated FDA recalls Z-1602-2023
- Recall initiated FDA recalls Z-1601-2023
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 5x95 Optical Trocar EUDAMEDYelloPort Elite GUDID
- Generic name
- Laparoscopic trocar blade, single-use
- Model / reference
- EO0509505
- Primary DI / UDI-DI
- 05051986013411
- Basic UDI-DI
- B-05051986013411
- 510(k) Number
- FDA product code
- GCJ
- EMDN code
- K01010103 Optical trocar, single-use
- GMDN term
- Laparoscopic trocar blade, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 876.1500
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Ireland
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIa | Class II |
Manufacturer details
- EUDAMED SRN
- GB-MF-000012187
- Authorised representative
- CS Life Sciences Europe Ltd IE-AR-000004113
Similar devices in this category
Other devices filed under OPTICAL TROCAR, SINGLE-USE.
- Disposable Bladeless Trocar, Disposable Optical Trocar, Disposable Blunt-Tip Trocar, Disposable Spiral Trocar, Disposable Bladed Trocar by Changzhou Xin Neng Yuan Medical Stapler Co., Ltd.
- Trocar kit UNTB-RC0510 by UNIMICRO MEDICAL SYSTEMS (SHENZHEN) CO., LTD.
- Laport N21-0575 by Sejong Medical Co., Ltd
- Trocar kit UNTR-C0507 by UNIMICRO MEDICAL SYSTEMS (SHENZHEN) CO., LTD.
- Visible Trocar UNTR-C1110 by Unimicro Medical Systems (ShenZhen) Co., Ltd.
- Visible Balloon Trocar UNTB-RC1210 by Unimicro Medical Systems (ShenZhen) Co., Ltd.
- Optical Cannula, 5 x 70mm PS5537 by Purple Surgical Holdings Limited also known as Purple Surgical International Limited, Purple Surgical UK Limited and Purple Surgical Manufacturing Limited
- Optical Trocar, 5 x 100mm PS5525NS by Purple Surgical Holdings Limited also known as Purple Surgical International Limited, Purple Surgical UK Limited and Purple Surgical Manufacturing Limited
- Laport N21-1110 by Sejong Medical Co., Ltd
- acetate optical frames ID Tokyo GLF5910 by Wenzhou XinRui Glasses Co., Ltd.