8 Fr.-40cc Arrow Flex Intra-Aortic Balloon Catheter with Blue Flex Tip, Product Number Iab-04840(Used with a 9FR.SHEATH)
510(k) K960713
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK960713 | Date15 May 1996 | StatusActive |
Recalls
No FDA recalls found in the data synced 6 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DSP
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.3535
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 22 Sep 2026
This device is an intra-aortic balloon catheter designed for use with an intra-aortic balloon pump control system. It is indicated for use in acute coronary syndrome, cardiac and non-cardiac surgery, and complications of heart failure. The catheter features a flexible tip and is constructed to function as a temporary circulatory support device within the aorta.
The device is supplied as a single-use, sterile product intended for clinical settings where temporary cardiac support is required. It is classified under FDA product code DSP and is regulated under 21 CFR 870.3535 as a Class II device. The catheter is 8 French in diameter with a 40 cc balloon volume and is used in conjunction with a 9 French sheath. Storage conditions and specific handling instructions are detailed in the manufacturer's labeling.
Other devices from Arrow Intl., Inc.
Questions
AI-generated answers, 22 Sep 2026
What clinical indications is the Arrow Flex IAB-04840 designed for?
This intra-aortic balloon catheter is indicated for acute coronary syndrome, cardiac and non-cardiac surgery, and complications of heart failure. It serves as a temporary circulatory support device within the aorta when used with an intra-aortic balloon pump control system.
How is the device supplied and is it intended for single or multiple patient use?
The device is supplied as a single-use, sterile product. It is intended for one-time clinical use and should be discarded after the procedure, in accordance with the manufacturer's labeling and standard infection control practices.
What are the key dimensional and compatibility specifications of this catheter?
The catheter has an 8 French diameter and a 40 cc balloon volume. It is designed to be used in conjunction with a 9 French sheath, which is necessary for proper insertion and function during temporary cardiac support procedures.
Under what regulatory classification and product code is this device categorized?
The device is classified under FDA product code DSP and is regulated under 21 CFR 870.3535 as a Class II device. This classification reflects its role as a temporary circulatory support system with established safety and performance standards.
What storage and handling conditions should be followed prior to use?
Specific storage conditions and handling instructions are detailed in the manufacturer's labeling. Healthcare professionals should consult the product insert for guidance on proper storage, inspection, and preparation before clinical use to ensure device integrity and patient safety.