{
  "format": "devicerts.device.v1",
  "cite_as": "A8, A9 Anesthesia System, Shenzhen Mindray Bio-Medical Electronics Co., Ltd. deviCERTS medical device catalogue. https://devicerts.com/devices/a8-a9-anesthesia-system-bsz (data as of 2026-11-27).",
  "source": {
    "canonical_url": "https://devicerts.com/devices/a8-a9-anesthesia-system-bsz",
    "json_url": "https://devicerts.com/devices/a8-a9-anesthesia-system-bsz.json",
    "markdown_url": "https://devicerts.com/devices/a8-a9-anesthesia-system-bsz.md",
    "publisher": "deviCERTS (devicerts.com)",
    "data_sources": [
      {
        "registry": "FDA 510(k)",
        "url": "https://open.fda.gov/apis/device/510k/"
      },
      {
        "registry": "EUDAMED",
        "url": "https://ec.europa.eu/tools/eudamed"
      },
      {
        "registry": "FDA recalls",
        "url": "https://open.fda.gov/apis/device/recall/"
      }
    ],
    "registry_records_last_synced": "2026-10-22",
    "status_as_of": "2026-11-27",
    "license": "CC BY 4.0",
    "license_url": "https://creativecommons.org/licenses/by/4.0/",
    "license_scope": "The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.",
    "attribution": "DevicErts, https://devicerts.com/devices/a8-a9-anesthesia-system-bsz",
    "disclaimer": "Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails."
  },
  "device": {
    "name": "A8, A9 Anesthesia System",
    "registry_name": "A8, A9 Anesthesia System",
    "url": "https://devicerts.com/devices/a8-a9-anesthesia-system-bsz",
    "manufacturer": {
      "name": "Shenzhen Mindray Bio-Medical Electronics Co., Ltd.",
      "url": "https://devicerts.com/manufacturers/shenzhen-mindray-bio-medical-electronics-co-ltd",
      "country": "China",
      "country_basis": null,
      "fda_registration_country": null
    },
    "status": {
      "state": "active",
      "label": "Active",
      "detail": "European Union and United States"
    },
    "classification": [
      {
        "class": "Class II",
        "system": "US FDA"
      }
    ],
    "identifiers": [
      {
        "label": "510(k) Number",
        "values": [
          {
            "value": "K201957",
            "registries": [
              "FDA 510(k)"
            ]
          }
        ]
      }
    ],
    "product_codes": [
      "BSZ"
    ],
    "emdn": [],
    "gmdn": [],
    "description": {
      "text": "The A8, A9 Anesthesia System is a Gas-Machine, Anesthesia, designed for the precise delivery of anesthetic gases and vapors during surgical procedures. It integrates ventilation, monitoring, and gas blending capabilities to support controlled anesthesia administration in clinical settings, ensuring patient safety and procedural efficacy.\n\nThis system is supplied as a reusable medical device, intended for use in operating rooms and anesthesia care areas. It adheres to FDA 510(k) clearance and MDD regulatory standards, with a classification as a Class II device under 21 CFR 868.5160. The system is non-MRI compatible and requires proper calibration, maintenance, and storage per manufacturer guidelines to maintain performance and sterility.",
      "ai_generated": true,
      "generated_on": "2026-09-18",
      "note": "Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record."
    },
    "noindex": false
  },
  "authorizations": [
    {
      "registry": "510(k)",
      "region": "United States",
      "type": "FDA 510(k)",
      "number": "K201957",
      "number_label": null,
      "device_udi_di": null,
      "date": "2021-03-26",
      "date_kind": "decision",
      "decision_code": "SESE",
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    },
    {
      "registry": "EUDAMED",
      "region": "European Union",
      "type": "CE/MDD",
      "number": null,
      "number_label": null,
      "device_udi_di": null,
      "date": null,
      "date_kind": null,
      "decision_code": null,
      "expires": null,
      "withdrawn": null,
      "status": "Active",
      "status_note": null,
      "derived_from_gudid": false
    }
  ],
  "no_longer_listed_by": [],
  "certificates": [],
  "recalls": [
    {
      "number": "Z-0720-2026",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2025-10-20",
      "reason": "Potential for anesthesia leakage.",
      "applies": "this device",
      "via": "K201957"
    },
    {
      "number": "Z-0721-2026",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2025-10-20",
      "reason": "Potential for anesthesia leakage.",
      "applies": "this device",
      "via": "K201957"
    },
    {
      "number": "Z-2949-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-07-22",
      "reason": "V90 electronic vaporizer anesthetic agent output may be higher than the set amount due to a component within the vaporizer causing an incomplete seal in some cases. Should this issue occur, the A9 Anesthesia System will generate alarms associated with abnormal vaporizer output. If the anesthetic concentration is too high, the patient can inhale too much anesthetic agent; the\npatient may suffer from symptoms such as vertigo and drowsiness after the operation. In severe\ncases, the patient may suffer from neurological sequelae such as hypomnesia and inattention",
      "applies": "this device",
      "via": "K201957"
    },
    {
      "number": "Z-2950-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-07-22",
      "reason": "V90 electronic vaporizer anesthetic agent output may be higher than the set amount due to a component within the vaporizer causing an incomplete seal in some cases. Should this issue occur, the A9 Anesthesia System will generate alarms associated with abnormal vaporizer output. If the anesthetic concentration is too high, the patient can inhale too much anesthetic agent; the\npatient may suffer from symptoms such as vertigo and drowsiness after the operation. In severe\ncases, the patient may suffer from neurological sequelae such as hypomnesia and inattention",
      "applies": "this device",
      "via": "K201957"
    },
    {
      "number": "Z-2951-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-07-22",
      "reason": "V90 electronic vaporizer anesthetic agent output may be higher than the set amount due to a component within the vaporizer causing an incomplete seal in some cases. Should this issue occur, the A9 Anesthesia System will generate alarms associated with abnormal vaporizer output. If the anesthetic concentration is too high, the patient can inhale too much anesthetic agent; the\npatient may suffer from symptoms such as vertigo and drowsiness after the operation. In severe\ncases, the patient may suffer from neurological sequelae such as hypomnesia and inattention",
      "applies": "this device",
      "via": "K201957"
    },
    {
      "number": "Z-2952-2024",
      "classification": "Class II",
      "status": "ongoing",
      "initiated": "2024-07-22",
      "reason": "V90 electronic vaporizer anesthetic agent output may be higher than the set amount due to a component within the vaporizer causing an incomplete seal in some cases. Should this issue occur, the A9 Anesthesia System will generate alarms associated with abnormal vaporizer output. If the anesthetic concentration is too high, the patient can inhale too much anesthetic agent; the\npatient may suffer from symptoms such as vertigo and drowsiness after the operation. In severe\ncases, the patient may suffer from neurological sequelae such as hypomnesia and inattention",
      "applies": "this device",
      "via": "K201957"
    }
  ],
  "eu_market_availability": null,
  "properties": [
    {
      "group": "Identifiers",
      "fields": [
        {
          "label": "510(k) Number",
          "values": [
            {
              "value": "K201957",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "FDA product code",
          "values": [
            {
              "value": "BSZ",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        }
      ]
    },
    {
      "group": "Classification",
      "fields": [
        {
          "label": "Device class",
          "values": [
            {
              "value": "Class II",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "Regulation",
          "values": [
            {
              "value": "21 CFR Part 868.5160",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "Advisory committee",
          "values": [
            {
              "value": "Anesthesiology",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        },
        {
          "label": "FDA decision",
          "values": [
            {
              "value": "SESE",
              "registries": [
                "FDA 510(k)"
              ]
            }
          ]
        }
      ]
    }
  ]
}
