Abbott Cell-Dyn 4000 System

by Abbott Diagnostics

510(k) K961439

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

7 closed

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK961439 Date18 Oct 1996ClearedStatusActive

Recalls

7 recalls · FDA

    • Terminated Z-1623-2011 FDA Unclassified (pre-2012) initiated 29 Dec 2009

    A component used in assembly is out of specification, resulting in failure to retract, eject specimens, exposure below the safety zone, piercing of specimen tubes, or error message to display.

    • Terminated Z-1103-2008 FDA Unclassified (pre-2012) initiated 19 Dec 2007 on shared 510(k) K961439

    Microbial Contamination: The WBC (White Blood Cell) Reagent Part A was confirmed positive for Pseudomonas contamination.

    • Terminated Z-0565-2007 FDA Unclassified (pre-2012) initiated 22 Dec 2006 on shared 510(k) K961439

    Results for tests of RBC, MCV, RDW, MPV and PLT may be falsely elevated or falsely decreased when the Cell Dyn Diluent/Sheath reagent is used with Cell-Dyn 4000, Ruby and Sapphire systems.

    • Terminated Z-0708-2007 FDA Unclassified (pre-2012) initiated 17 Apr 2006 on shared 510(k) K961439

    High platelet background count when using the CELL-DYN 4000 System and/or CELL-DYN Sapphire System; with patient results unacceptable -out-of-range.

    • Terminated Z-0639-2007 FDA Unclassified (pre-2012) initiated 12 May 2004 on shared 510(k) K961439

    Incorrect Test Results-test results may show a higher than expected platelet background count when used on the CELL-DYN 4000 System and report patient results that are unacceptable (out-of-range).

    • Terminated Z-0640-2007 FDA Unclassified (pre-2012) initiated 24 Feb 2004 on shared 510(k) K961439

    Incorrect Test Results-product may show a higher than expected platelet background count when used on the CELL-DYN 4000 System and report patient results that are unacceptable (out-of-range).

    • Terminated Z-0648-03 FDA Unclassified (pre-2012) initiated 16 Oct 2002

    Product elicits fluorescent signal interference due to contamination.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
GKZ
Device Class
Class II
Regulation
21 CFR Part 864.5220
Advisory Committee
Hematology
FDA Decision
SESE Substantially Equivalent