# ABL8X7 Flex

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/abl8x7-flex-cgl>
- Manufacturer: [Radiometer Medical ApS](https://devicerts.com/manufacturers/radiometer-medical-aps) (FDA registration: Denmark)
- Name in the registry: ABL8X7 FLEX
- Device class: Class II (US FDA)
- FDA product code: CGL

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K051968 · decision 2006-10-16 · decision SESE · status: Active

## Recalls

- Z-0801-2019 · Class II · terminated · initiated 2018-07-02 · matched through shared submission K051968, may concern other models: From three incidents in Denmark and Sweden, comparison studies on patient blood samples carried out for quality assurance demonstrated that creatinine measurements as determined on analyzers could be underestimated with up to 28% as compared with measurements from COBAS. The underestimated creatinine occurs specifically, when measurements on Autocheck 6+ level 1 (also known as S7835 Autocheck module and abbreviated AC6+L1) are less than or equal to 230 micro-meter of a specified insert interval for AC6+L1 with insert limits 210 290 micro-meter. Ultimately, a lower read-out on patient samples is observed Customers are concerned about underestimation of creatinine results in patients, which are to undergo radiocontrast x-ray investigations. If these patients are not healthy, the exposure of radiocontrast agents may induce kidney insufficiency (contrast-induced nephropathy). Hazardous situation: Underestimation of the concentration of creatinine.
- Z-1293-2015 · Class II · terminated · initiated 2014-10-29: Negative drift on QC during in-use lifetime of CREA membranes can be observed.
- Z-1008-2012 ·  · terminated · initiated 2011-12-16: When the user activates the dosicap (containing the crea additive) and mounts it onto the bottle, the threads will not seal correctly causing approximately 10% of the solution to leak out when the bottle is placed horizontally for dissolving the additive. This will cause the concentration of creatinin and creatin in the calibration solution to be wrong, and results in a bias on the Crea results.
- Z-1015-2010 ·  · terminated · initiated 2009-03-26: Analysis of customer data, (for ABL 8X7 customers) has shown that the reference membranes are out of analytical specifications when replaced as specified in the device labeling. These errors in analytical specifications could lead to inadequate or clinical interventions (therapy) or misleading interpretation of patient status in clinical settings.

## Identifiers

- 510(k) Number: K051968 [FDA 510(k)]
- FDA product code: CGL [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 862.1225 [FDA 510(k)]
- Advisory committee: Clinical Chemistry [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: ABL8X7 Flex, Radiometer Medical ApS. deviCERTS medical device catalogue. https://devicerts.com/devices/abl8x7-flex-cgl (data as of 2026-11-24).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-10
- Statuses computed as of: 2026-11-24
- JSON: <https://devicerts.com/devices/abl8x7-flex-cgl.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/abl8x7-flex-cgl
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.