# ABL90 Flex Series

> Active: United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/abl90-flex-series-cem>
- Manufacturer: [Radiometer Medical ApS](https://devicerts.com/manufacturers/radiometer-medical-aps) (FDA registration: Denmark)
- Name in the registry: ABL90 FLEX SERIES
- Device class: Class II (US FDA)
- FDA product code: CEM

## Registrations and authorizations

- **510(k)** · FDA 510(k) · United States · K092686 · decision 2010-08-06 · decision SESE · status: Active

## Recalls

- Z-1659-2025 · Class II · ongoing · initiated 2025-03-21 · matched through shared submission K092686, may concern other models: ABL90 FLEX and ABL90 FLEX PLUS analyzers running with Radiometer Windows 10 versions RWIN10 1.0 and RWIN10 1.1 may unexpectedly freeze (the analyzer ceases to operate) during a sample measurement. The analyzer software includes a feature (watchdog) that detects a freeze and automatically restarts the software to continue operating the analyzer. However, even if a restart occurs, any sample being processed at that time will be lost, potential to lead to delay in test results.
- Z-1858-2021 · Class II · ongoing · initiated 2021-04-14: Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed.
- Z-1856-2021 · Class II · ongoing · initiated 2021-04-14: Due to an issue with the internal clock of the analyzers with an e3800 PC unit installed.
- Z-1760-2020 · Class II · terminated · initiated 2020-02-03: The firm received reports of occurrences where the barcode reader misinterpreted the contents of a locally printed barcode label used for entering patient ID or accession number into the analyzer in connection with a sample measurement. This could result is patient mixup and/or lost of sample, resulting in delayed medical treatment.
- Z-2139-2020 · Class II · terminated · initiated 2019-11-21 · matched through shared submission K092686, may concern other models: The analyzers fail on S7950 (Range +) QC measurements due to the hemolyzer cuvettes, a subcomponent of the optical system which measures ctHb and derivates. In a cuvette with light shunt, some of the received light has not been transmitted through the sample. This will lead to a perturbed and non-linear absorbance spectrum which results in measurement errors.
- Z-2320-2019 · Class II · terminated · initiated 2019-07-10: Software Security; The action is being initiated because of software security vulnerabilities with the firm's analyzer operating system, which may cause the device to shutdown or reboot resulting in delayed medical treatment.
- Z-1462-2017 · Class II · terminated · initiated 2017-01-26 · matched through shared submission K092686, may concern other models: Reports that the sample type "cord blood" has been changed into the two sample types "cord blood arterial" and "cord blood venous.
- Z-0816-2014 · Class II · terminated · initiated 2013-10-15 · matched through shared submission K092686, may concern other models: RADIOMETER become aware that if the ABL90 FLEX is tilted, this may potentially cause a negative bias on sodium (Na+) results.
- Z-2112-2011 ·  · terminated · initiated 2011-01-12: Following the receipt of two (2) reported customer complaints, the firm determined that the current operating software for their ABL 90 Analyzer does not prevent the further use of the sensor cassette when there is the possibility of iron rich plaque build-up in the reference electrode. If the device operator/user ignores the error message and continues to obtain biased measuring results using the
- Z-1011-2011 ·  · terminated · initiated 2010-11-01: Due to a software error, a patient mix up can occur on the ABL90. If a sample is pre-registered and the sample "fails" the next result will inherit the patient data from the previous result.

## Identifiers

- 510(k) Number: K092686 [FDA 510(k)]
- FDA product code: CEM [FDA 510(k)]

## Classification

- Device class: Class II [FDA 510(k)]
- Regulation: 21 CFR Part 862.1600 [FDA 510(k)]
- Advisory committee: Clinical Chemistry [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]

## Source and citation

- Cite as: ABL90 Flex Series, Radiometer Medical ApS. deviCERTS medical device catalogue. https://devicerts.com/devices/abl90-flex-series-cem (data as of 2026-11-17).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-17
- JSON: <https://devicerts.com/devices/abl90-flex-series-cem.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/abl90-flex-series-cem
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.