Identity
- Trade Name
- ABLATHERM FUSION FDA UDI
- Generic Name
- Physical therapy ultrasound system FDA UDI
- Device Name
- The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The system consists of the following main sub-assemblies: Therapy Control Module, Treatment Module, Endorectal Probe, and consumable Ablapak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume. FDA UDI
- Model / Reference
- EDP 900800 FDA UDI
- Description
- The device is a computer-controlled medical device intended to provide High Intensity Focused Ultrasound (also referred to as HIFU) to ablate prostate tissue. The system consists of the following main sub-assemblies: Therapy Control Module, Treatment Module, Endorectal Probe, and consumable Ablapak. HIFU is a unique process of delivering a large amount of heat energy to a confined space in a highly controlled manner. This energy heats the tissue to ablation levels while minimizing the effect on surrounding structures. The ultrasound energy is delivered via an endorectal probe, which includes an imaging system. The ultrasound waves propagate through the rectal wall and are focused on a portion of the prostate, generating intense heat and causing the ablation of tissue within the targeted area. The process is then repeated in a stepwise fashion to destroy the targeted tissues within the prostate. The apex, sphincter and rectum are preserved while prostate tissues are ablated.Imported diagnostic data can be fused with the real time ultrasound image in order to facilitate the targeting of the ablation volume. FDA UDI
Identifiers
- Primary DI / UDI-DI
- 03661690000199 FDA UDI
- FDA Product Code
- PLP FDA UDI
- GMDN Term
- Physical therapy ultrasound system FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 876.4340 FDA UDI
- Commercial Distribution
- Not in Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
Yes
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
No
FDA UDI
Serial Number
Yes
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Ablatherm Fusion by Edap-Tms France — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Edap-Tms France
Sources (1)
- FDA UDI 3438fee6-3b45-4850-bb2a-682e3a44ad6c 35 fields · synced May 30, 2026