Abx Pentra Reference 280ml 1220001901
by Horiba Abx
Ref A11A01901
Abx Pentra Reference 280ml 1220001901 is a device classified as IVD General (EU), Class II (US) made by Horiba Abx, registered in EUDAMED on 16 Jun 2026 (Basic UDI-DI B-03610230005613), cleared under FDA 510(k) K052007 on 16 Dec 2005 and listed in FDA GUDID since 16 Aug 2016 (UDI-DI 03610230005613), active as of 25 Oct 2026.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/IVDD EUDAMED | NumberB-03610230005613 03610230005613 | Date16 Jun 2026 | StatusActive |
| United States | GUDID listing GUDID | Number03610230005613 | Date16 Aug 2016 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK052007 | Date16 Dec 2005 | StatusActive |
Official records
- EUDAMED public site B-03610230005613
- AccessGUDID record 03610230005613
- FDA 510(k) database K052007
Across registries
- EUDAMED Basic UDI-DI B-03610230005613 registered 16 Jun 2026 Active
- FDA 510(k) K052007 decided 16 Dec 2005 Active
- FDA GUDID UDI-DI 03610230005613 listed 16 Aug 2016 Listed
Certificates
No certifier certificate is listed. Devices of this class are self-declared by the manufacturer.
Recalls
-
- Terminated Z-0493-2018
- Terminated Z-0494-2018
The ABX PENTRA Reagent Containers do not always sit properly into the reagent rack. In low reagent level scenarios, this could lead to insufficient reagent volume being pipetted and could lead to incorrect results being reported without an alarm.
-
- Terminated Z-0740-2016
N-Acetylcysteine (NAC) present in the blood of patients treated for paracetamol overdose can interfere with the Trinder reaction that uses hydrogen peroxide catalytic on aminoantipyrine and phenol, and can produce falsely low results with the reagents using the Trinder reaction method.
-
- Terminated Z-0902-2015
HORIBA Medical is recalling the ABX PENTRA 400 Reagent Container because they do not always sit properly into the reagent rack. In low reagent level scenarios, this could lead to insufficient reagent volume being pipetted and could lead to incorrect results being reported without an alarm. The defect would result in a false high or false low results for HbA1c and false high results for magnes
-
- Terminated Z-0904-2014
Horiba Medical is recalling the ABX PENTRA N Control because it has been updated to include a revised Target Value assignment for Potassium.
-
- Terminated Z-1141-2013
HORIBA Medical is informing all ABX PENTRA 400 Analyzer with I.S.E. Module customers that there are no Linearity Limit Flags for the I.S.E. assays currently programmed into the ABX PENTRA 400 Analyzer software. All other assays run on this analyzer do have Linearity Limit Flags to alert the user to values that fall below or above the validated linearity range for each assay.
Timeline
- Cleared FDA 510(k) K052007
- Recall initiated FDA recalls Z-1141-2013
- Recall initiated FDA recalls Z-0904-2014
- Recall initiated FDA recalls Z-0902-2015
- Recall initiated FDA recalls Z-0740-2016
- Listed FDA GUDID 03610230005613
- Recall initiated FDA recalls Z-0493-2018
- Recall initiated FDA recalls Z-0494-2018
- Registered EUDAMED B-03610230005613
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Abx Pentra Reference 280ml
- Generic name
- Multiple blood gas/haemoximetry/electrolyte analyte IVD, calibrator
- Model / reference
- A11A01901 EUDAMED1220001901 GUDID
- Primary DI / UDI-DI
- 03610230005613
- Basic UDI-DI
- B-03610230005613
- 510(k) Number
- FDA product code
- JIX
- EMDN code
- W0101050301 Calibrators multicomponent (cc)
- GMDN term
- Multiple blood gas/haemoximetry/electrolyte analyte IVD, calibrator
- Device class
- Class IVD General EUDAMEDClass II GUDID
- Regulation number
- 862.1150
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- France
- GUDID distribution status
- In Commercial Distribution
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Model / reference | A11A01901 | 1220001901 |
| Device class | Class IVD General | Class II |
Similar devices in this category
Other devices filed under CALIBRATORS MULTICOMPONENT (CC).
- Plasma Calibrator Set 92030 by Chromsystems Instruments & Chemicals GmbH
- Plasma Calibrator Set 92032 by Chromsystems Instruments & Chemicals GmbH
- Atellica CH CHEM III Calibrator 11099335 by Siemens Healthcare Diagnostics Inc.
- ARCHITECT 1E46-04 01E4604 by Abbott
- Direct LDL/HDL Cholesterol Calibrator CH2673 by RANDOX LABORATORIES LIMITED
- Dimension® TBI/DBI Calibrator 10445013 DC167 by Siemens Healthcare Diagnostics Inc.
- ISE blood sample calibrator 232030412202 by DIRUI INDUSTRIAL CO., LTD
- Calibrator for Automatic System (Multi-Cal) ECH0182999 by Maccura Biotechnology Co., Ltd.
- sCal 981831 by Thermo Fisher Scientific Oy
- Synchron 469965 by Beckman Coulter, Inc.