Skip to content

Access Vitamin B12 Assay, Access Ferritin Assay, Access Folate Assay, Access HYPERsensitive hTSH Assay, Power Express Sample Processing System Generic Connection Module and Access Immunoassay System Reagents

by Beckman Coulter, Inc.

510(k) K140496

Active European Union and United States

CE IVDR 510(k)

Valid until

Not listed

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

3 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source EUDAMED, FDA 510(k), synced 6 Oct 2026. What this means

Regulatory status

as of registry sync 6 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE 510(k) Substantially Equivalent · Special NumberK140496 Date16 Sep 2014ClearedStatusActive
European UnionCE/IVDR EUDAMED Number— Date—StatusActive

Recalls

4 recalls · 3 ongoing · FDA

  • 3 recalls, same reason

    • Ongoing Z-2978-2024 FDA Class II initiated 17 Jul 2024
    • Ongoing Z-2980-2024 FDA Class II initiated 17 Jul 2024
    • Ongoing Z-2979-2024 FDA Class II initiated 17 Jul 2024

    The adhesive joint between the plastic socket and metal component of the Power Express Sample Holder can fail, causing the metal part to detach and enter the centrifuge. This detachment can result in damage to the centrifuge and potential destruction of the patient sample resulting in delayed results and possible exposure of lab technician to biohazardous material.

    • Terminated Z-1741-2020 FDA Class II initiated 17 May 2019 on shared 510(k) K140496

    Potential exposure to biohazard. Software design problem causes excess speed and vibrations in the unload arm movement which causes caused sample splashing.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · 510(k)

510(k) Number
FDA Product Code
CDD
Device Class
Class II
Regulation
21 CFR Part 862.1810
Advisory Committee
Clinical Chemistry
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Access Vitamin B12 Assay, Access Ferritin Assay, Access Folate Assay, and Access HYPERsensitive hTSH Assay are radioassay devices designed for the quantitative determination of vitamin B12, ferritin, folate, and thyroid-stimulating hormone (TSH) in human serum and plasma (heparin). These assays utilize a paramagnetic particle chemiluminescent technology to measure analyte concentrations, supporting clinical chemistry diagnostics. The Power Express Sample Processing System Generic Connection Module facilitates automated sample processing integration within immunoassay systems.

These assays are supplied as sterile, single-use reagents intended for use with the Access Immunoassay System, a Class II medical device. The Power Express Sample Processing System Generic Connection Module is designed for compatibility with the system, ensuring seamless sample handling. The devices are authorized under FDA 510(k) clearance (K140496) and comply with In Vitro Diagnostic Regulation (IVDR) requirements. Storage and handling follow manufacturer guidelines to maintain assay integrity.

Other devices from Beckman Coulter, Inc.

See all devices from Beckman Coulter, Inc. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical chemistry assays are included in this Access Immunoassay System kit, and how are they used?

    This kit includes four radioassay-based tests: the Access Vitamin B12 Assay, Access Ferritin Assay, Access Folate Assay, and Access HYPERsensitive hTSH Assay. They measure vitamin B12, ferritin, folate, and thyroid-stimulating hormone (TSH) levels in human serum and plasma (heparinized), respectively, using paramagnetic particle chemiluminescent technology. These assays support clinical chemistry diagnostics by quantifying these analytes to aid in diagnosing deficiencies, storage disorders, or thyroid dysfunction.

  • Are the reagents single-use, and if so, why is this important for clinical workflows?

    Yes, the Access Immunoassay System reagents are supplied as sterile, single-use items. This design ensures each test is performed with fresh reagents, reducing the risk of contamination or degradation from repeated exposure to environmental factors. Single-use also streamlines workflows by eliminating the need for cleaning or reprocessing, which is particularly valuable in high-volume clinical settings where consistency and efficiency are critical.

  • How does the Power Express Sample Processing System Generic Connection Module integrate with the Access Immunoassay System, and what role does it play?

    The Power Express Sample Processing System Generic Connection Module is designed to facilitate automated sample processing within the Access Immunoassay System. It ensures seamless compatibility, allowing for efficient handling and preparation of samples before analysis. This integration helps standardize workflows, reduce manual errors, and improve throughput in laboratories using the system.

  • What regulatory pathways have these assays undergone, and what does that mean for their use in clinical settings?

    The assays are authorized under both FDA 510(k) clearance (K140496) and comply with the In Vitro Diagnostic Regulation (IVDR). This means they have undergone rigorous review to demonstrate safety, performance, and equivalence to existing devices, ensuring they meet stringent regulatory standards for clinical use. Clinicians can rely on these assays as validated tools for accurate diagnostic testing in their workflows.

  • How should these reagents be stored to maintain their integrity, and why is proper storage important?

    Storage and handling of these reagents must follow the manufacturer’s guidelines to preserve assay integrity. While the exact conditions aren’t specified here, proper storage typically involves protecting reagents from light, extreme temperatures, and contamination. This is critical because improper storage can degrade the reagents, leading to inaccurate test results or compromised performance, which could impact patient diagnosis or treatment decisions.