Skip to content

Accu-Chek Guide 07400870001

by Roche Diagnostics Operations, Inc.

Accu-Chek Guide 07400870001, a glucose IVD (FDA Class II; FDA product code NBW, System, Test, Blood Glucose, Over The Counter) made by Roche Diagnostics Operations, Inc., was cleared under FDA 510(k) K160944 on 31 Aug 2016 and listed in FDA GUDID on 2 Feb 2017 (UDI-DI 00365702702035); the registry lists it as not in commercial distribution (GUDID) as of 23 Oct 2026. FDA recalls on record: 2.

Active United States. Also listed in GUDID (US), not in commercial distribution.

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

510(k) K160944

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00365702702035 UDI-DI Date2 Feb 2017ListedStatusListed GUDID: not in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK160944 Date31 Aug 2016DecidedStatusActive

Official records

From the FDA record

Device description
ACCU-CHEK GUIDE SAMPLE KIT MG/DL
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K160944 decided 31 Aug 2016 Active
  • FDA GUDID UDI-DI 00365702702035 listed 2 Feb 2017 Listed

Recalls

2 recalls · 1 ongoing · FDA

    • Ongoing Z-2174-2024 FDA Class II initiated 13 May 2024

    The reason for recall is the meters may show an incorrect measurement unit (mmol/L rather than mg/dL) and may result in the wrong unit of measure. Which may subsequently cause an error in interpreting a result as approximately 18 times lower that the actual blood glucose. Potential immediate health consequences of the glucose meter providing a reading in the wrong units of measurement (UOM) may result in inappropriate rescue therapy for presumed hypoglycemia including urgent and repeat administration of carbohydrates. This in turn could lead to frequent episodes of hyperglycemia which is unrecognized and undertreated.Long range consequences of continued use of the affected meters could include mismanagement of the patient s diabetes for longer periods of time potentially resulting in a major health event (in general persistent and/or severe hyperglycemia) that may lead them to seek medical attention, and depending on the duration of hyperglycemia, could contribute to the development of microvascular (i.e., retinopathy, neuropathy, nephropathy) and/or macrovascular (i.e., myocardial infarction, ischemic stroke) complications of diabetes and could lead to fetal damage (abnormal fetal growth and altered organ development and maturation, fetal hypoxemia, spontaneous abortion, and congenital anomalies) in pregnant women. This issue was identified by three initial consumer complaints, with reports that the meters were presenting the incorrect unit of measure.

    • Terminated Z-0747-2020 FDA Class II initiated 30 Sep 2019

    Potential power issues with the Accu-Chek Guide Blood Glucose Monitoring System.

Timeline

4 dated events

  1. Cleared FDA 510(k) K160944
  2. Listed FDA GUDID 00365702702035
  3. Recall initiated FDA recalls Z-0747-2020
  4. Recall initiated FDA recalls Z-2174-2024

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Accu-Chek Guide
Generic name
Glucose IVD, kit, spectrophotometry
Model / Ref / Catalog
07400870001
Primary DI / UDI-DI
00365702702035
510(k) Number
FDA product code
NBW
GMDN term
Glucose IVD, kit, spectrophotometry
Device class
Class II
Regulation number
862.1345
GUDID distribution status
Not in Commercial Distribution

Similar devices

Other devices filed under FDA product code NBW (System, Test, Blood Glucose, Over The Counter).

Other devices from Roche Diagnostics Operations, Inc.

See all devices from Roche Diagnostics Operations, Inc. →

Properties

  • Convenience kit
  • Lot / batch number
  • Serial number
  • Expiration date
Other properties (11, all answered No)