Skip to content

Acetabular Dome Hole Plugs

by Osteonics Corp.

510(k) K942809

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK942809 Date20 Sep 1994ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
JDL
Device Class
Class III
Regulation
21 CFR Part 888.3320
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Acetabular Dome Hole Plugs are classified as Prosthesis, Hip, Semi-Constrained (Metal Cemented Acetabular Component) under FDA nomenclature. These devices are designed to fill and seal perforations or screw holes in acetabular components during hip replacement surgery, preventing fluid leakage and ensuring structural integrity of the implant.

These hole plugs are intended for use in orthopedic surgical settings and are supplied as reusable medical devices. They are regulated under FDA 510(k) clearance (K942809) and fall under product code JDL, classified as Class III orthopedic devices. No information regarding sterility or MRI safety is provided in the available data.

Other devices from Osteonics Corp.

See all devices from Osteonics Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • Are these hole plugs intended for single-use or can they be reused in multiple procedures?

    The Acetabular Dome Hole Plugs are explicitly described as reusable medical devices, meaning they are designed to be used in multiple surgical procedures after proper cleaning and sterilization between cases. This classification aligns with their intended use in orthopedic settings where durability and repeated application are required.

  • What sizes or models are available for these acetabular dome hole plugs, and how are they differentiated?

    The data lists multiple FEI numbers (e.g., 3020282716, 1047843, etc.) associated with these hole plugs, which typically correspond to distinct sizes or variations in design. While the exact dimensions or model names aren’t specified, the presence of numerous FEI numbers suggests a range of sizes to accommodate different acetabular component perforations or screw holes. For precise sizing, refer to the manufacturer’s catalog or technical documentation.

  • How are these hole plugs regulated in the U.S., and what does the FDA clearance indicate about their safety and effectiveness?

    These hole plugs are regulated under the FDA 510(k) clearance process (K942809) and fall under product code JDL, classified as Class III orthopedic devices. The clearance indicates that the manufacturer has demonstrated the device is substantially equivalent to a legally marketed predicate, meaning it meets the same safety and performance standards as an existing, approved device. This does not imply new clinical breakthroughs but confirms compliance with regulatory requirements for use in hip replacement surgeries.

  • Are these hole plugs compatible with MRI imaging, and what should clinicians consider regarding their use?

    The provided data does not mention MRI safety for the Acetabular Dome Hole Plugs, meaning no information is available to confirm or deny their compatibility with MRI imaging. Clinicians should consult the manufacturer’s instructions or additional documentation to assess potential risks (e.g., metal artifacts, heating) before using these devices in patients who may require MRI scans post-surgery. Always verify compatibility with the specific MRI system in use.