Achieva Family

by Philips Medical Systems North America Co.

510(k) K043147

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

3 ongoing

Recall on shared 510(k) K043147; other models may be affected

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK043147 Date15 Feb 2005ClearedStatusActive

Recalls

13 recalls · 3 ongoing · FDA

  • 3 recalls, same reason

    • Ongoing Z-2165-2024 FDA Class I initiated 5 Jun 2024 on shared 510(k) K043147
    • Ongoing Z-2164-2024 FDA Class I initiated 5 Jun 2024 on shared 510(k) K043147
    • Ongoing Z-2163-2024 FDA Class I initiated 5 Jun 2024 on shared 510(k) K043147

    Potential for coils to heat up and harm patients (burn).

  • 10 recalls, same reason

    • Terminated Z-0928-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0884-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0893-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0914-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0905-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0913-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0906-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0907-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0927-2019 FDA Class II initiated 21 Dec 2018
    • Terminated Z-0897-2019 FDA Class II initiated 21 Dec 2018

    There is a potential for the ceiling speaker(s) to fall from their position and be pulled to the MR system by the magnetic field.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
LNH
Device Class
Class II
Regulation
21 CFR Part 892.1000
Advisory Committee
Radiology
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Achieva Family is a series of Nuclear Magnetic Resonance Imaging (MRI) Systems, classified as Class 2 devices under FDA regulations. These systems are designed to generate detailed images of the human body using strong magnetic fields and radio waves, enabling diagnostic evaluation of soft tissues, organs, and skeletal structures. The devices are intended for use in radiology departments to assist in the detection, diagnosis, and monitoring of a wide range of medical conditions, including neurological, cardiovascular, and musculoskeletal disorders. Their advanced imaging capabilities support high-resolution visualization for precise clinical assessments.

The Achieva Family is supplied as reusable medical equipment, intended for use in clinical settings such as hospitals and radiology centers. These MRI systems are not single-use and require proper maintenance, calibration, and adherence to manufacturer guidelines for safe operation. The devices are regulated under FDA 510(k) clearance (K043147) and fall under the classification of Radiation-Emitting Products, specifically MRI systems. They are designed for MRI-safe environments, adhering to strict electromagnetic compatibility and safety standards. Multiple model variants are listed, each corresponding to specific registration numbers and technical configurations.

Other devices from Philips Medical Systems North America, Inc.

See all devices from Philips Medical Systems North America, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Achieva Family used for in clinical settings?

    The Achieva Family MRI Systems are designed to generate detailed images of the human body using strong magnetic fields and radio waves. These systems assist in diagnosing and monitoring a wide range of medical conditions, including neurological disorders (e.g., brain or spinal issues), cardiovascular problems (e.g., heart or blood vessel assessments), and musculoskeletal disorders (e.g., joint or bone abnormalities). Their advanced imaging capabilities enable precise visualization of soft tissues, organs, and skeletal structures, supporting accurate clinical evaluations.

  • How is the Achieva Family supplied and intended for use?

    The Achieva Family MRI Systems are supplied as reusable medical equipment, intended exclusively for use in clinical environments such as hospitals and radiology centers. Unlike single-use devices, these systems require regular maintenance, calibration, and adherence to manufacturer guidelines to ensure safe and reliable operation. Their design supports long-term clinical use in MRI-safe environments, adhering to strict electromagnetic compatibility and safety standards.

  • Are there multiple models in the Achieva Family, and how are they differentiated?

    Yes, the Achieva Family includes multiple model variants, each corresponding to specific registration numbers and technical configurations. These models are differentiated by their unique identifiers (e.g., FEI numbers like 3008156140 or 3021593788) and tailored specifications to meet varying clinical needs. The manufacturer provides detailed documentation for each variant to ensure proper selection, installation, and operation based on the intended diagnostic applications.

  • What regulatory pathway does the Achieva Family follow?

    The Achieva Family MRI Systems are classified as Class 2 devices under FDA regulations and have obtained FDA 510(k) clearance (K043147). This pathway confirms that the devices are substantially equivalent to a legally marketed predicate device, ensuring they meet established safety and performance standards. The systems are also regulated under the Radiation-Emitting Products category, specifically for MRI systems, and must comply with electromagnetic compatibility and safety standards for MRI-safe environments.

  • How should the Achieva Family MRI Systems be stored and maintained?

    The Achieva Family MRI Systems require proper storage and maintenance to ensure optimal performance and safety. They should be stored in a controlled environment, protected from physical damage, extreme temperatures, and electromagnetic interference. Regular maintenance, including calibration and servicing by trained technicians, is essential to uphold the system’s accuracy, reliability, and compliance with manufacturer guidelines. Adherence to these protocols extends the device’s lifespan and ensures consistent diagnostic imaging quality.