Skip to content

Acoustic Impedance Meter, Model TA-4D

by Teledyne Avionics Div. of Teledyne

510(k) K801293

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK801293 Date17 Jun 1980ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
ETY
Device Class
Class II
Regulation
21 CFR Part 874.1090
Advisory Committee
Ear, Nose, Throat
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Acoustic Impedance Meter, Model TA-4D, is a Class II medical device classified as a Tester, Auditory Impedance. It measures acoustic impedance in the ear canal, providing objective data on middle ear function, tympanic membrane mobility, and acoustic reflex thresholds. This assessment aids in diagnosing conditions such as otitis media, Eustachian tube dysfunction, or hearing impairment.

The device is intended for use in clinical settings by healthcare professionals in the Ear, Nose, and Throat specialty. Supplied as a reusable instrument, it requires no sterilization between uses. The TA-4D operates under FDA 510(k) clearance (K801293) and falls under regulation 874.1090, with a traditional review pathway. No MRI safety or single-use specifications are noted in the regulatory data.

Other devices from Teledyne Avionics Div. of Teledyne

See all devices from Teledyne Avionics Div. of Teledyne →

Questions

AI-generated answers, 19 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What clinical conditions can the Acoustic Impedance Meter, Model TA-4D, help diagnose or assess in patients?

    The TA-4D measures acoustic impedance in the ear canal to evaluate middle ear function, tympanic membrane mobility, and acoustic reflex thresholds. This objective data helps diagnose conditions like otitis media, Eustachian tube dysfunction, or hearing impairments, particularly in clinical Ear, Nose, and Throat settings.

  • Is the Acoustic Impedance Meter, Model TA-4D, intended for single-use or reusable applications, and does it require sterilization?

    The TA-4D is designed as a reusable instrument and does not require sterilization between uses, as specified in its regulatory documentation. This makes it suitable for repeated clinical assessments without additional processing.

  • What regulatory pathway was followed for the FDA clearance of the Acoustic Impedance Meter, Model TA-4D?

    The TA-4D received FDA clearance through a 510(k) submission (K801293) under the traditional review pathway, classified as a Class II device under regulation 874.1090. The submission was reviewed by the Ear, Nose, and Throat (EN) Advisory Committee in 1980.

  • Which medical specialties would primarily benefit from using the Acoustic Impedance Meter, Model TA-4D?

    The TA-4D is explicitly intended for use in Ear, Nose, and Throat (ENT) clinical settings, where professionals assess middle ear health, tympanic membrane integrity, and hearing-related conditions. Its design aligns with diagnostic needs in this specialty.