Skip to content

Acs Hi-Torque Cross-It Guide Wire with Hydrocoat Hydrophilic Coating Product Family Models 1003211H, 1003212HJ, 1003213H, 1

by Guidant Corp.

510(k) K981381

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK981381 Date15 Jul 1998ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
DQX
Models / Variants
1
Device Class
Class II
Regulation
21 CFR Part 870.1330
Advisory Committee
Cardiovascular
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 22 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The ACS Hi-Torque Cross-It Guide Wire with Hydrocoat Hydrophilic Coating is a cardiovascular guide wire featuring a stainless steel core wire with a 0.014-inch nominal diameter and a radiopaque distal tip available in straight or J-shaped configurations. The distal portion is coated with HYDROCOAT™ hydrophilic coating, while the proximal section is coated with polytetrafluoroethylene to facilitate delivery and maneuverability during vascular procedures.

This device is supplied as part of a product family including models 1003211H, 1003212HJ, 1003213H, and 1, and was cleared by the FDA through the 510(k) process under K981381. It is intended for use in cardiovascular applications and requires proper handling to maintain the lubricity of its hydrophilic coating. The device is not described as sterile, single-use, or reusable in the provided data, and no MRI safety information is specified.

Other devices from Guidant Corp.

See all devices from Guidant Corp. →

Questions

AI-generated answers, 22 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the ACS Hi-Torque Guide Wire used for?

    The ACS Hi-Torque Guide Wire is intended for use in cardiovascular applications, facilitating delivery and maneuverability during vascular procedures.

  • What are the key features of the Hydrocoat hydrophilic coating?

    The Hydrocoat hydrophilic coating is applied to the distal portion of the guide wire, while the proximal section is coated with polytetrafluoroethylene to facilitate delivery and maneuverability.

  • How is the device supplied and what models are available?

    The device is supplied as part of a product family, including models 1003211H, 1003212HJ, 1003213H, and 1, with varying configurations such as straight or J-shaped.

  • What is the regulatory status of the ACS Hi-Torque Guide Wire?

    The device was cleared by the FDA through the 510(k) process under K981381, determined to be substantially equivalent.