Acs Hi-Torque Cross-It Guide Wire with Hydrocoat Hydrophilic Coating Product Family Models 1003211H, 1003212HJ, 1003213H, 1
510(k) K981381
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK981381 | Date15 Jul 1998 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DQX
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1330
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 22 Sep 2026
The ACS Hi-Torque Cross-It Guide Wire with Hydrocoat Hydrophilic Coating is a cardiovascular guide wire featuring a stainless steel core wire with a 0.014-inch nominal diameter and a radiopaque distal tip available in straight or J-shaped configurations. The distal portion is coated with HYDROCOAT™ hydrophilic coating, while the proximal section is coated with polytetrafluoroethylene to facilitate delivery and maneuverability during vascular procedures.
This device is supplied as part of a product family including models 1003211H, 1003212HJ, 1003213H, and 1, and was cleared by the FDA through the 510(k) process under K981381. It is intended for use in cardiovascular applications and requires proper handling to maintain the lubricity of its hydrophilic coating. The device is not described as sterile, single-use, or reusable in the provided data, and no MRI safety information is specified.
Other devices from Guidant Corp.
Questions
AI-generated answers, 22 Sep 2026
What is the ACS Hi-Torque Guide Wire used for?
The ACS Hi-Torque Guide Wire is intended for use in cardiovascular applications, facilitating delivery and maneuverability during vascular procedures.
What are the key features of the Hydrocoat hydrophilic coating?
The Hydrocoat hydrophilic coating is applied to the distal portion of the guide wire, while the proximal section is coated with polytetrafluoroethylene to facilitate delivery and maneuverability.
How is the device supplied and what models are available?
The device is supplied as part of a product family, including models 1003211H, 1003212HJ, 1003213H, and 1, with varying configurations such as straight or J-shaped.
What is the regulatory status of the ACS Hi-Torque Guide Wire?
The device was cleared by the FDA through the 510(k) process under K981381, determined to be substantially equivalent.