Skip to content

Actim PROM Controls 30800ETUS

by Actim Oy

Actim PROM Controls 30800ETUS is an in vitro diagnostic device (FDA Class I; FDA product code OAM, Immunoassay, Insulin-Like Growth Factor Binding Protein-1) made by Actim Oy, cleared under FDA 510(k) K123986 on 9 Jan 2014, registered in EUDAMED and listed in FDA GUDID since 28 Feb 2019 (UDI-DI 06430030990622), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union and United States. Also listed in GUDID (US).

CE IVDD 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

1 ongoing

This device is named in the recall

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K123986

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing GUDID Number06430030990622 UDI-DI Date28 Feb 2019ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Traditional NumberK123986 Date9 Jan 2014DecidedStatusActive
European UnionCE/IVDD EUDAMED Number— Date—StatusActive

Official records

From the FDA record

Device description
The Actim PROM Controls kit consists of one of each of the following components: 1. Actim PROM Negative Control (0 μg/L) 2. Actim PROM Low Positive Control (40 μg/L) 3. Actim PROM High Positive Control (250 μg/L) 4. Actim Reconstitution Solution 5. Instructions for use
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • FDA 510(k) K123986 decided 9 Jan 2014 Active
  • EUDAMED Active
  • FDA GUDID UDI-DI 06430030990622 listed 28 Feb 2019 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-1592-2024 FDA Class II initiated 23 Nov 2023

    Interference testing has shown that the presence of personal lubricants in the vaginal specimen can interfere with the PROM test result by providing a false positive result.

Timeline

3 dated events

  1. Cleared FDA 510(k) K123986
  2. Listed FDA GUDID 06430030990622
  3. Recall initiated FDA recalls Z-1592-2024

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDD Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Actim PROM Controls
Generic name
Insulin-like growth factor binding protein 1 (IGFBP-1) IVD, control
Model / reference
30800ETUS
Primary DI / UDI-DI
06430030990622
510(k) Number
FDA product code
OAM
GMDN term
Insulin-like growth factor binding protein 1 (IGFBP-1) IVD, control
Device class
Class I
Regulation number
862.1550
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code OAM (Immunoassay, Insulin-Like Growth Factor Binding Protein-1).

Other devices from Actim Oy

See all devices from Actim Oy →

Properties

  • Single use
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (10, all answered No)