Acumed 7003-07036
by Acumed LLC
Ref 7003-07036
Acumed 7003-07036 is an orthopaedic fixation plate (EU MDD Class IIb; FDA Class I; FDA product code LXH, Orthopedic Manual Surgical Instrument) made by Acumed LLC, registered in EUDAMED on 28 Oct 2026 (Basic UDI-DI B-10806378036415), cleared under FDA 510(k) K123890 on 18 Mar 2013 and listed in FDA GUDID since 24 Oct 2015 (UDI-DI 10806378036415), active as of 7 Nov 2026.
Active
Valid until
No date given
FDA recalls
None ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDD EUDAMED | NumberB-10806378036415 10806378036415 | Date28 Oct 2026 | StatusActive |
| United States | GUDID listing GUDID | Number10806378036415 | Date24 Oct 2015 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK123890 | Date18 Mar 2013 | StatusActive |
Official records
- EUDAMED public site B-10806378036415
- AccessGUDID record 10806378036415
- FDA 510(k) database K123890
From the FDA record
- Device description
- Cann. Screw Washer 7.0mm OD X 3.6mm ID
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI B-10806378036415 registered 28 Oct 2026 Active
- FDA 510(k) K123890 decided 18 Mar 2013 Active
- FDA GUDID UDI-DI 10806378036415 listed 24 Oct 2015 Listed
Recalls
-
- Completed Z-0958-2022
- Completed Z-0959-2022
Cannulated Screws 4.0mm x 10mm and 4.0mm x 12mm may not have sufficient axial pullout strength for the indicated use. Remote possibility of resulting in a mal or nonunion of the bone fragments, iatrogenic fracture, joint impingement or damage, or soft tissue damage.
Timeline
- Cleared FDA 510(k) K123890
- Listed FDA GUDID 10806378036415
- Recall initiated FDA recalls Z-0958-2022
- Recall initiated FDA recalls Z-0959-2022
- Registered EUDAMED B-10806378036415
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Acumed
- Generic name
- Orthopaedic fixation plate, non-bioabsorbable
- Device name
- Screw
- Model / reference
- 7003-07036
- Primary DI / UDI-DI
- 10806378036415
- Basic UDI-DI
- B-10806378036415
- 510(k) Number
- FDA product code
- LXH
- EMDN code
- P09120601 Cortical screws
- GMDN term
- Orthopaedic fixation plate, non-bioabsorbable
- Device class
- Class IIb EUDAMEDClass I GUDID
- Regulation number
- 888.4540
- EU registration type
- Legacy device (under a directive)
- EU market of registration
- Spain
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class I |
Similar devices in this category
Other devices filed under CORTICAL SCREWS.
- 4845-46-04 00-4845-046-04 by Zimmer, Inc.
- CORTICAL SCREW 8150-37-065 815037065 by Biomet Orthopedics, Inc.
- TraumaOne SYSTEM 41-2014 by BIOMET MICROFIXATION, INC
- A.L.P.S.® 8550-37-036 855037036 by Biomet Orthopedics, Inc.
- Omni Stable AF 144-28032 by Extremity Medical, LLC
- 4845-42-04 00-4845-042-04 by Zimmer, Inc.
- 4.0mm Cancellous Screw, Partially Threaded T52034040 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- 2.4mm Cortical Screw(Self-tapping) T50012406 by Tianjin Zhengtian Medical Instrument Co., Ltd.
- "2.0MM" SYSTEM 99-9474 by BIOMET MICROFIXATION, INC
- Omni Stable AF 144-35034 by Extremity Medical, LLC