Ref AIQS6R5
Acumen IQ AIQS6R5 is an invasive-pressure external transducer (EU MDR Class IIa; FDA Class II; FDA product code DRS, Transducer, Blood-Pressure, Extravascular) made by Edwards Lifesciences LLC, registered in EUDAMED on 30 Sep 2026 (Basic UDI-DI 0690103D001FAS000PZ), cleared under FDA 510(k) K152980 on 19 Jan 2016 and listed in FDA GUDID since 27 Aug 2024 (UDI-DI 00690103220353), active as of 22 Oct 2026. 4 FDA recalls are linked to it.
Active
Valid until
No date given
FDA recalls
4 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number0690103D001FAS000PZ 00690103220353 | Date30 Sep 2026 | StatusActive |
| United States | GUDID listing GUDID | Number00690103220353 | Date27 Aug 2024 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK152980 | Date19 Jan 2016 | StatusActive |
Official records
- EUDAMED public site 0690103D001FAS000PZ
- AccessGUDID record 00690103200959
- FDA 510(k) database K152980
From the FDA record
- Device description
- ACUMEN IQ SENSOR 60" / 152CM with Red Cap
- MRI safety
- MR Conditional
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- EUDAMED Basic UDI-DI 0690103D001FAS000PZ registered 30 Sep 2026 Active
- FDA 510(k) K152980 decided 19 Jan 2016 Active
- FDA GUDID UDI-DI 00690103220353 listed 27 Aug 2024 Listed
Recalls
-
- Ongoing Z-0409-2024
- Ongoing Z-0410-2024
- Ongoing Z-0412-2024
- Ongoing Z-0411-2024
Their is the potential for flushing difficulties during setup of the pressure monitoring kit with pressure transducer.
Timeline
- Cleared FDA 510(k) K152980
- Recall initiated FDA recalls Z-0409-2024
- Recall initiated FDA recalls Z-0410-2024
- Recall initiated FDA recalls Z-0412-2024
- Recall initiated FDA recalls Z-0411-2024
- Listed FDA GUDID 00690103220353
- Registered EUDAMED 0690103D001FAS000PZ
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- Acumen IQ
- Generic name
- Invasive-pressure external transducer, single-use
- Device name
- Hemodynamic Monitoring Disposables (Sterile, Single Use, Active, Non-Implantable)
- Model / Ref / Catalog
- AIQS6R5
- Description
- ACUMEN IQ SENSOR 60" / 152CM with Red Cap
- Primary DI / UDI-DI
- 00690103220353 EUDAMED00690103200959 GUDID
- Basic UDI-DI
- 0690103D001FAS000PZ
- 510(k) Number
- FDA product code
- DRS
- EMDN code
- Z1203020301 Invasive blood pressure monitoring instruments
- GMDN term
- Invasive-pressure external transducer, single-use
- Device class
- Class IIa EUDAMEDClass II GUDID
- Regulation number
- 870.2850
- EU registration type
- Standard device
- EU market of registration
- Netherlands
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
- Size
- Length — 60 Inch
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Primary DI / UDI-DI | 00690103220353 | 00690103200959 |
| Device class | Class IIa | Class II |
Similar devices in this category
Other devices filed under INVASIVE BLOOD PRESSURE MONITORING INSTRUMENTS.
- DELTRAN Standard Bifurcated Kit DP2-400 by Utah Medical Products, Inc.
- OptoMonitor F2000 by Opsens
- Meritrans DTXPlus® 10884450371739 682002/B by ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
- NAMIC 70030021 by MEDLINE INDUSTRIES, INC.
- Meritrans DTXPlus® 10884450373009 by ARGON CRITICAL CARE SYSTEMS SINGAPORE PTE. LTD.
- Meritrans® 00884450240434 K11-00096B by Merit Medical Systems, Inc.
- TRAM® 00884450312353 203LTPHWF-R/D by Merit Medical Systems, Inc.
- DELTRAN PLUS ABC KIT AB2-400-6 by Utah Medical Products, Inc.
- NAMIC 70038307 by MEDLINE INDUSTRIES, INC.
- Unimed DP-MX by Unimed Medical Supplies, Inc.