Acuson

by Siemens Medical Solutions USA, Inc. 4 variants

510(k) K123622

Acuson is a Class II device made by Siemens Medical Solutions USA, Inc., cleared under FDA 510(k) K123622 on 5 Dec 2012, active as of 22 Oct 2026. 12 FDA recalls are linked to it.

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

13 closed

Documents

Trust

Unverified

Source FDA 510(k), synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK123622 Date5 Dec 2012ClearedStatusActive

Official records

Recalls

13 recalls · FDA

    • Terminated Z-0667-2017 FDA Class II initiated 7 Nov 2016

    Firm received reports about "acquisition errors" and the deterioration of material covering the articulating section of the Z6Ms transesophageal transducer.

    • Terminated Z-1592-2016 FDA Class II initiated 8 Apr 2016

    While imaging with a transesophageal (TEE) transducer (Z6Ms, V5Ms, or V7M), user may lose the ability to control the color region of interest, the pulsed wave or continuous wave Doppler gate or cursor, the M-mode cursor, the 2D field of view, or the RES region of interest with the trackball.

    • Terminated Z-0182-2016 FDA Class II initiated 7 Oct 2015

    Siemens will provide all customers a new version of system software (VA35E or VB10C depending on the hardware configuration). Hardware fixes will be implemented to address situations where the metal component used to engage the wheel lock becomes disconnected, and where the system locks up due to misalignment between the bezel and MPI board, in all units that have not already been corrected.

    • Terminated Z-2783-2015 FDA Class II initiated 19 Aug 2015

    The ACUSON SC2000 ultrasound system considers uppercase/lowercase differences in the same patient name as unique patient instances when registered on the same ultrasound system. If these differences are not corrected at the time of registration, the system does not capture images or clips.

    • Terminated Z-1056-2015 FDA Class II initiated 12 Jan 2015

    The bolt holding the control panel of the ACUSON SC2000 in a fixed position may fail and the Control panel cannot be locked into position.

    • Terminated Z-1668-2014 FDA Class II initiated 23 Apr 2014

    Potential malfunction due to a software issue for ACUSON SC2000 ultrasound systems using software version 3.5 (VA35) when using the stress echo feature which could cause the need for the study to be repeated.

    • Terminated Z-1667-2014 FDA Class II initiated 23 Apr 2014

    Software issues with ACUSON SC2000 ultrasound with software version 3/5 (VA35) - may incorrectly display the color flow data in the wrong position and when Doppler Frequency is adjusted, the system does not restart the pulsed wave Doppler or continuous wave Doppler waveform.

    • Terminated Z-0824-2014 FDA Class II initiated 22 Dec 2013

    The user interface assembly on the ACUSON SC2000 may become loose with the potential for the entire module to fall off of the ultrasound system.

    • Terminated Z-0825-2014 FDA Class II initiated 22 Dec 2013

    The locking mechanism that is intended to hold the control panel in a fixed position can become loose and fail to lock the rotation of the control panel, making it unable to steer or control during transport.

    • Terminated Z-0052-2014 FDA Class II initiated 10 Jul 2013

    Software issue results in inaccurate 3D image may result in ablation in wrong location.

    • Terminated Z-1081-2013 FDA Class II initiated 28 Mar 2013

    When using the V5M transducer, the display of the temperature on the ACUSON SC2000 system can be lower than the actual temperature of the V5M transducer. This occurs only if the system hardware contains revision 4 of the MPI Board. There is a potential to cause esophageal burns in patients.

    • Terminated Z-1584-2015 FDA Class II initiated 11 Jul 2012

    In certain situations, loss of post exercise images can occur in Stress Echo.

    • Terminated Z-1581-2015 FDA Class II initiated 11 May 2012 on shared 510(k) K123622

    In some cases, the system is unable to capture a clip or image during a routine scan.

Recalls on a shared submission name another device cleared under the same FDA submission as this one.

Timeline

14 dated events

  1. Recall initiated FDA recalls Z-0052-2014
  2. Recall initiated FDA recalls Z-0824-2014
  3. Recall initiated FDA recalls Z-0825-2014
  4. Recall initiated FDA recalls Z-1668-2014
  5. Recall initiated FDA recalls Z-1667-2014
  6. Recall initiated FDA recalls Z-1056-2015
  7. Recall initiated FDA recalls Z-2783-2015
  8. Recall initiated FDA recalls Z-0182-2016
  9. Recall initiated FDA recalls Z-1592-2016
  10. Recall initiated FDA recalls Z-0667-2017

4 earlier events are in the sections above.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA product code
IYN
Device class
Class II
Regulation
21 CFR Part 892.1550
Advisory committee
Radiology
FDA decision
SESE Substantially Equivalent

Devices cleared under K123622

1 device · FDA GUDID

Devices that FDA's GUDID lists as cleared or approved under this submission number. One submission usually covers a whole product family, so the sizes and models are listed here once.

Devices cleared under K123622
UDI-DISize and differences
4Z1c Transducer 10033682
SIEMENS MEDICAL SOLUTIONS USA, INC.
10031838 / 1003368204056869005423 —On the market

Similar devices

Other devices filed under FDA product code IYN (System, Imaging, Pulsed Doppler, Ultrasonic).

Other devices from Siemens Medical Solutions USA, Inc.

See all devices from Siemens Medical Solutions USA, Inc. →