Skip to content

Depth Electrode

by Ad-Tech Medical Instrument Corp. 2 variants

510(k) K891920

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK891920 Date27 Jul 1989ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

Full name
Ad-Tech's Depth Electrode
510(k) Number
FDA product code
GZL
FDA applicant
Ad-Tech Medical Instrument Corp
Device class
Class II
Regulation
21 CFR Part 882.1330
Advisory committee
Neurology
FDA decision
SESE Substantially Equivalent

Overview

AI-generated summary, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Depth Electrode is a medical device classified as an Electrode, Depth under FDA nomenclature, designed for intracranial recording and monitoring of electrical activity within the brain. It facilitates precise localization of epileptic foci and other neurological signals by positioning electrodes at specific depths, enabling detailed brain mapping and seizure monitoring during both intraoperative and long-term studies.

This device is supplied sterile and intended for single-use, adhering to FDA’s 510(k) clearance (K891920) under the GZL product code for Class II Neurology applications. It is intended for use in MRI-safe environments and must be handled and stored according to manufacturer guidelines to maintain sterility. The device is regulated under 21 CFR 882.1330 and is not reusable.

From the manufacturer

Ad-Tech Medical Instrument Corporation The World's Leader As the world leader, Ad-Tech's electrode devices are used in surgical cases for long-term EEG monitoring*, brain mapping, SEEG, and brain stimulation of persons with intractable epilepsy and other brain diseases/disorders. *Long Term Monitoring: Device use is indicated for up to 29 days.

Source: adtechmedical.com

Ad-Tech Medical offers high-performance depth electrodes for sEEG diagnostics, subsurface brain mapping, and epilepsy monitoring.

Source: adtechmedical.com

Other devices from Ad-Tech Medical Instrument Corp.

See all devices from Ad-Tech Medical Instrument Corp. →

Questions

AI-generated answers, 18 Sep 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the primary clinical purpose of the Depth Electrode, and how does it differ from surface electrodes in brain monitoring?

    The Depth Electrode is specifically designed for intracranial recording to monitor electrical activity within the brain at precise depths. Unlike surface electrodes, which only capture signals from the brain’s outer layers, this device allows for detailed localization of epileptic foci and other neurological signals by positioning electrodes at targeted depths. This enables accurate brain mapping and seizure monitoring during both intraoperative procedures and long-term studies, making it ideal for complex neurological assessments.

  • Is the Depth Electrode reusable, and if not, what are the implications for clinical workflows?

    No, the Depth Electrode is intended for single-use only and is supplied sterile. This design ensures patient safety by eliminating the risk of cross-contamination between uses. Clinicians must adhere to manufacturer guidelines for handling and storage to maintain sterility, which may require additional planning for inventory and disposal in clinical workflows.

  • Can this device be used in MRI environments, and what precautions should be taken during its use?

    Yes, the Depth Electrode is designed for use in MRI-safe environments. However, it must be handled and stored according to the manufacturer’s guidelines to preserve its MRI compatibility and sterility. Clinicians should confirm compatibility with their specific MRI system and follow all safety protocols to avoid interference or damage to the device.

  • What regulatory pathway was followed for this device, and how does that affect its use in clinical settings?

    The Depth Electrode received FDA clearance through a 510(k) submission (K891920) under the GZL product code, classified as a Class II device under 21 CFR 882.1330. This clearance indicates it meets FDA standards for safety and effectiveness in neurology applications, specifically for intracranial recording and monitoring. Clinicians can rely on this regulatory status to ensure the device adheres to established medical device guidelines for use in neurological procedures.