Adapta™ ADSR06
Adapta™ ADSR06 is a Class III device made by Medtronic, Inc., approved under FDA PMA P980035 on 29 Jan 1999 and listed in FDA GUDID since 28 Nov 2020 (UDI-DI 00763000316792), active as of 23 Oct 2026. 13 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
13 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number00763000316792 | Date28 Nov 2020 | StatusListed |
| United States | FDA PMAAPPR | NumberP980035 | Date29 Jan 1999 | StatusActive |
Official records
- AccessGUDID record 00763000316792
- FDA PMA database P980035
Across registries
- FDA PMA P980035 decided 29 Jan 1999 Active
- FDA GUDID UDI-DI 00763000316792 listed 28 Nov 2020 Listed
Recalls
-
- Ongoing Z-2128-2025
- Ongoing Z-2127-2025
A software update for Medtronic CareLink SmartSync Device Manager (SmartSync) is now available. The update eliminates the potential display of an erroneous electrical reset (pop-up) message upon interrogation with a SmartSync Device Manager. The erroneous message indicates an electrical reset has occurred. However, no reset has actually occurred and there are no parameter changes or loss of diagnostics. Prior to this software update, if an erroneous SmartSync message was displayed, confusion regarding the message could have caused a clinician to consider an unnecessary system revision. Medtronic has received 39 reports of this display error with two instances of unnecessary device explant through 30 April 2025.
-
- Ongoing Z-1924-2025
Identified devices may experience sudden battery power failure without alarm, power supply power-on-resets, and interruption of therapy. Potential patient harms include insufficient pacing support leading to cardiac arrest, syncope, or hospitalization; or system revision (explant/replacement) leading to infection, hematoma, or temporary impairment.
-
- Ongoing Z-2510-2020
- Ongoing Z-2509-2020
- Ongoing Z-2508-2020
- Ongoing Z-2507-2020
There is a rare communication sequence during the first device interrogation with a SmartSync Device Manager that may result in the temporary suspension of some device features (i.e., battery measurements, Capture Management", Atrial Lead Position Check", EffectivCRT" algorithms, and AdaptivCRT"). This rare interaction results in temporary suspension of automatic threshold testing and output adjustments, and suspension of auto-optimization of CRT therapy. The issue is unlikely to result in clinical impact to the patient, and features are restored upon next programmer device interrogation or presence of a magnet.
-
- Ongoing Z-0811-2019
- Ongoing Z-0808-2019
- Ongoing Z-0810-2019
- Ongoing Z-0809-2019
- Ongoing Z-0806-2019
- Ongoing Z-0807-2019
A subset of Medtronic dual chamber pacemakers distributed worldwide between 10 March 2017 and 7 January 2019 under the brand names Adapta, Versa, and Sensia when programmed to a dual chamber mode with atrial-sensing, may experience a circuit error that affects device functionality
-
- Terminated Z-2120-2011
A rare measurement lock-up condition that may (at a rate of approximately 1 in 18,000 devices) inappropriately trigger ERI/RRT in the Medtronic Dual Chamber Pacemakers: Kappa 600, 700, 800, 900, EnPulse, Adapta, Versa, Sensia. This is caused by a random lock-up of the measurement system hardware that may result in an incorrect battery voltage reading of zero. This issue does NOT impact battery lon
-
- Terminated Z-1440-2010
Medtronic is informing doctors of two specific battery issues with EnRhythm pacemakers that will be addressed by a Medtronic software update available mid-2010. If the software update referenced above is not implemented, there will be a potential risk of loss of device functionality or risk for loss of therapy at or near ERI in a small number of devices. The software will eliminate this issue, fo
-
- Terminated Z-1515-2009
One or more bond wire pairs will lift or separate from the bonding terminals on the device hybrid. This may present clinically as loss of rate response, premature battery depletion, loss of telemetry, or no output.
Timeline
- Recall initiated FDA recalls Z-0806-2019
- Recall initiated FDA recalls Z-0807-2019
- Recall initiated FDA recalls Z-2510-2020
- Recall initiated FDA recalls Z-2509-2020
- Recall initiated FDA recalls Z-2508-2020
- Recall initiated FDA recalls Z-2507-2020
- Listed FDA GUDID 00763000316792
- Recall initiated FDA recalls Z-1924-2025
- Recall initiated FDA recalls Z-2128-2025
- Recall initiated FDA recalls Z-2127-2025
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA PMA Active
Specification
- Trade name
- Adapta™
- Generic name
- Single-chamber implantable pacemaker, rate-responsive
- Model / reference
- ADSR06
- Primary DI / UDI-DI
- 00763000316792
- PMA number
- FDA product code
- LWP, NVZ
- GMDN term
- Single-chamber implantable pacemaker, rate-responsive
- Device class
- Class III
- GUDID distribution status
- In Commercial Distribution