AEON
Ref AEPH160, ASR30PS, AEPH060, AESR45B, ASR60WS, AETH060, AESR60W, AESH260, AETH160, AESR45W, ASR30WS, ASR45RS, AESC45W, AESC60W, AESR45P, ASR30GS, AESH160, ASR30RC, AESR60B, ASR30WC, AESR60R, AESR45R, AESPHCU, AESC60P, ASR30PC510(k) K192235
AEON (AEPH160) is a medical device (EU MDR Class IIa; EU MDR Class IIb; FDA Class II; EMDN category single patient articulated linear staplers with blade for laparoscopy) made by Lexington Medical Inc., registered in EUDAMED on 5 Feb 2025 (Basic UDI-DI B-00850060791079) with CE/MDR certificate G70 003029 0010 valid until 29 Sep 2031, cleared under FDA 510(k) K234039 on 7 May 2024 (3 earlier submissions) and listed in FDA GUDID since 29 Jan 2018 (UDI-DI 00850060791079), active as of 8 Nov 2026.
Active
Valid until
29 Sep 2031
FDA recalls
None found
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | NumberG70 003029 0010 | Date30 Sep 2026 | StatusActive |
| European Union | CE/MDD EUDAMED | NumberB-00850060791079 | Date5 Feb 2025 | StatusActive |
| United States | FDA 510(k)SESE GUDID | NumberK234039 | Date7 May 2024 | StatusActive |
| United States | FDA 510(k)SESE 510(k) | NumberK192235 | Date11 Oct 2019 | StatusActive |
| United States | GUDID listing GUDID | Number00850060791079 | Date29 Jan 2018 | StatusListed |
Official records
- EUDAMED public site B-00850060791079
- AccessGUDID record 00850060791079
- AccessGUDID record 00851574008509
- AccessGUDID record 00850060791062
- AccessGUDID record 00851574008363
- AccessGUDID record 00851574008905
- FDA 510(k) database K234039
- FDA 510(k) database K192235
- FDA 510(k) database K180114
- FDA 510(k) database K171589
From the FDA record
FDA 510(k) K192235
- Received by the FDA
- 19 Aug 2019
- FDA decision
- 11 Oct 2019 (Substantially Equivalent)
- FDA review time
- 53 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
FDA 510(k) K180114
- Received by the FDA
- 16 Jan 2018
- FDA decision
- 27 Mar 2018 (Substantially Equivalent)
- FDA review time
- 70 days from receipt to decision
- Public document
- 510(k) summary on file with the FDA
Across registries
- EUDAMED Basic UDI-DI B-00850060791079 registered 5 Feb 2025 Active
- FDA 510(k) K234039 decided 7 May 2024 Active
- FDA GUDID UDI-DI 00850060791079 listed 29 Jan 2018 Listed
Certificates
- G70 003029 0010 Active
Technical documentation EU MDR
- Certifier
- TÜV SÜD Product Service GmbH 0123
- Issued
- 30 Sep 2026
- Expires
- 29 Sep 2031
Timeline
- Cleared FDA 510(k) K171589
- Listed FDA GUDID 00850060791079
- Cleared FDA 510(k) K180114
- Cleared FDA 510(k) K192235
- Cleared FDA 510(k) K234039
- Registered EUDAMED B-00850060791079
- Certificate issued EUDAMED G70 003029 0010
- Certificate expires EUDAMED G70 003029 0010
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Generic name
- Endoscopic manual linear cutting stapler, single-useMotorized cutting stapler handpiece
- Device name
- AEON Endoscopic Powered Stapler Handle - MediumAEON Endoscopic Powered Stapler Handle - ShortAEON Endoscopic Stapler 45mm Reload, 5.0mm/2.2mmAEON Endoscopic Stapler Plus Handle ShortAEON Endoscopic Powered StaplerAEON Endoscopic Stapler Handle LongAEON Endoscopic Stapler 45mm Short Tip Reload, 3.25mm/1.5mmAEON Endoscopic Stapler 60mm Curved Tip Reload, 2.5mm/1.0mmAEON Endoscopic Stapler 45mm Reload, 4.0mm/1.8mmAEON Endoscopic Stapler 30mm Short Tip Reload, 2.0mm/0.75mmAEON Endoscopic Stapler Handle MediumAEON Endoscopic Stapler 45mm Reload, 3.25mm/1.5mmAEON Control UnitAEON Endoscopic Stapler 60mm Curved Tip Reload, 4.0mm/1.8mm
- Model / Ref / Catalog
- AEPH160, ASR30PS, AEPH060, AESR45B, ASR60WS, AETH060, AESR60W, AESH260, AETH160, AESR45W, ASR30WS, ASR45RS, AESC45W, AESC60W, AESR45P, ASR30GS, AESH160, ASR30RC, AESR60B, ASR30WC, AESR60R, AESR45R, AESPHCU, AESC60P, ASR30PC, AESC45R, AESR45G
- Primary DI / UDI-DI
- 00850060791079, 00851574008516, 00851574008509, 00850060791062, 00851574008295, 00851574008233, 00851574008653, 00851574008462, 00851574008912, 00851574008035, 00851574008363, 00851574008899, 00851574008332, 00851574008905, 00850060791116, 00851574008103, 00851574008882, 00851574008257, 00851574008646, 00851574008875, 00851574008387, 00851574008011, 00851574008585, 00851574008714, 00851574008318, 00851574008660, 00851574008813, 00850060791093, 00851574008172, 00851574008523, 00851574008004, 00851574008325, 00851574008301, 00851574008769, 00851574008967, 00851574008028, 00851574008844, 00851574008707, 00851574008110, 00851574008226
- Basic UDI-DI
- B-00850060791079, B-00851574008516, B-00851574008509, B-00850060791062, B-00851574008295, B-00851574008233, B-00851574008653, 0851574008ENDOSHANDLEZS, B-00851574008912, B-00851574008035, B-00851574008363, B-00851574008899, B-00851574008332, B-00851574008905, B-00850060791116, B-00851574008103, B-00851574008882, B-00851574008257, B-00851574008646, B-00851574008875, B-00851574008387, B-00851574008011, B-00851574008585, B-00851574008714, B-00851574008318, B-00851574008660, B-00851574008813, B-00850060791093, B-00851574008172, B-00851574008523
- FDA product code
- GCJ 510(k)GEI 510(k)GDW GUDIDGAG GUDID
- EMDN code
- H020301050102 Single patient articulated linear staplers with blade for laparoscopy
- GMDN term
- Endoscopic manual linear cutting stapler, single-useMotorized cutting stapler handpiece
- Device class
- Class IIa EUDAMEDClass IIb EUDAMEDClass II 510(k)GUDID
- Regulation
- 21 CFR Part 876.1500 510(k)21 CFR Part 878.4400 510(k)878.4750 GUDID878.4740 GUDID
- EU registration type
- Legacy device (under a directive)Standard device
- EU market of registration
- AustriaBelgiumCzechiaFranceFinland
- Advisory committee
- Gastroenterology, UrologyGeneral, Plastic Surgery
- FDA decision
- SESE Substantially Equivalent
- GUDID distribution status
- In Commercial Distribution
- MRI safety
- MR Conditional
Truth per registry
| Field | EUDAMED | 510(k) | GUDID |
|---|---|---|---|
| 510(k) Number | — | K180114 K192235 | K171589 K234039 |
| FDA product code | — | GCJ GEI | GDW GAG |
| Device class | Class IIa Class IIb | Class II | Class II |
| Regulation number | — | 876.1500 878.4400 | 878.4750 878.4740 |
| Supplied sterile | Yes No | — | Yes |
| Sterilise before use | Yes No | — | No |
| Implantable | No Yes | — | No |
| Contains latex | No | — | No Yes |
Registry differences
EUDAMED and FDA GUDID describe the same product (same UDI-DI) and state different values:
- Sterilise before use UDI-DI 00850060791079: EUDAMED states Yes, FDA GUDID states No.
- Sterilise before use UDI-DI 00851574008509: EUDAMED states Yes, FDA GUDID states No.
- Sterilise before use UDI-DI 00850060791062: EUDAMED states Yes, FDA GUDID states No.
- Sterilise before use UDI-DI 00851574008363: EUDAMED states Yes, FDA GUDID states No.
- Sterilise before use UDI-DI 00851574008905: EUDAMED states Yes, FDA GUDID states No.
- Contains latex UDI-DI 00851574008363: EUDAMED states No, FDA GUDID states Yes.
Device class is stated on each registry's own scale: Class IIa and Class IIb in the EU (EUDAMED), Class II in the US (FDA 510(k), FDA GUDID). EU and US classes are different schemes.
Manufacturer details
- EUDAMED SRN
- US-MF-000007741
- FDA applicant
- Lexington Medical, Inc.
- Authorised representative
- Advena Limited MT-AR-000000234
Similar devices in this category
Other devices filed under SINGLE PATIENT ARTICULATED LINEAR STAPLERS WITH BLADE FOR LAPAROSCOPY.
- TOUCHSTONE ® Bendos Q™Powered Universal Handle TSF-M by Touchstone International Medical Science Co., Ltd.
- Cartridge for Disposable Endoscopic Cutter Stapler 12028045 by Changzhou Waston Medical Appliance Co., Ltd
- Mirus™ Endocutter ME/BRC/STA/004 by Meril Endo Surgery Pvt. Ltd.
- ETHICON EC3D60C by Ethicon Endo-Surgery, LLC
- TOUCHSTONE ELC-GM by Touchstone International Medical Science Co., Ltd.
- ETHICON EC3D60L by Ethicon Endo-Surgery, LLC