Skip to content

Agee WristJack® CFD-147

by Hand Biomechanics Lab

Agee WristJack CFD-147 is an orthopaedic bone pin (FDA Class II; FDA product code JEC, Component, Traction, Invasive) made by Hand Biomechanics Lab, cleared under FDA 510(k) K984442 on 12 Feb 1999 and listed in FDA GUDID since 23 Oct 2015 (UDI-DI 00861994000205), active as of 22 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K984442

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number00861994000205 UDI-DI Date23 Oct 2015ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK984442 Date12 Feb 1999DecidedStatusActive

Official records

From the FDA record

Device description
Fracture Reduction System. Fracture reduction and external fixation for treatment of distal radius fractures.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied sterile

From the GUDID record (AccessGUDID), as read on 22 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K984442 decided 12 Feb 1999 Active
  • FDA GUDID UDI-DI 00861994000205 listed 23 Oct 2015 Listed

Recalls

1 recall · FDA

    • Terminated Z-0136-2017 FDA Class II initiated 14 Sep 2016

    A number of Agee WristJack Fracture Reduction Systems have been manufactured with a molded beam slightly larger than optimal. This may result in the surgeon experiencing difficulty fine-tuning the length (red) and radial/ulnar alignment (blue) adjustments on the device.

Timeline

3 dated events

  1. Cleared FDA 510(k) K984442
  2. Listed FDA GUDID 00861994000205
  3. Recall initiated FDA recalls Z-0136-2017

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Agee WristJack®
Generic name
Orthopaedic bone pin, non-bioabsorbable
Model / reference
CFD-147
Primary DI / UDI-DI
00861994000205
510(k) Number
FDA product code
JEC
GMDN term
Orthopaedic bone pin, non-bioabsorbable
Device class
Class II
Regulation number
888.3040
GUDID distribution status
In Commercial Distribution

Similar devices in this category

Other devices filed under Orthopaedic bone pin, non-bioabsorbable.

Other devices from Hand Biomechanics Lab

Properties

  • Supplied sterile
  • Single use
  • Implantable
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (9, all answered No)