Identity
- Trade Name
- AI Metrics FDA UDI
- Generic Name
- Radiological PACS software FDA UDI
- Device Name
- AI Metrics is a thin client software application used with general purpose computing hardware for the display and visualization of medical image data, supporting images and anatomical datasets, such as CT and MR. AI Metrics is designed as a workflow automation application with analytical tools to help the user assess, categorize and document the extent of a disease and/or tumor response to therapy in accordance with user selected standards (e.g. RECIST 1.1) and assess changes in imaging findings over multiple time-points. AI Metrics supports the interpretation and evaluation of examinations and follow up documentation of findings within healthcare institutions, for example, in Radiology, Oncology, and other Medical Imaging environments. AI Metrics functionality provides for communication, storage, processing, rendering, and display of DICOM compliant image data derived from various sources, navigation through images, selection of regions of interest, generation of information from those regions, evaluation in accordance with user selected standards, and generation of a structured report. The user controls these functions with a system of interactive menus and semi-automated or manual workflow automation tools, including: • Manual annotation tools for users to select regions of interest (ROIs), • Semi-automatic lesion segmentation suggestions for user-selected ROIs, • Automatic measurement and display of long and short axis of segmented lesions, • Automatic tabulation and summation of measurements, • Semi-automatic lesion labelling suggestions for anatomical location (organ, body region, and laterality), • Automatic calculation of quantitative and qualitative metrics using annotation data in accordance with the selected criteria, and • Automatic generation of a structured report that includes the annotation data and calculated quantitative and qualitative metrics presented in a graph, table, key images, and structured text report. FDA UDI
- Model / Reference
- 1 FDA UDI
- Description
- AI Metrics is a thin client software application used with general purpose computing hardware for the display and visualization of medical image data, supporting images and anatomical datasets, such as CT and MR. AI Metrics is designed as a workflow automation application with analytical tools to help the user assess, categorize and document the extent of a disease and/or tumor response to therapy in accordance with user selected standards (e.g. RECIST 1.1) and assess changes in imaging findings over multiple time-points. AI Metrics supports the interpretation and evaluation of examinations and follow up documentation of findings within healthcare institutions, for example, in Radiology, Oncology, and other Medical Imaging environments. AI Metrics functionality provides for communication, storage, processing, rendering, and display of DICOM compliant image data derived from various sources, navigation through images, selection of regions of interest, generation of information from those regions, evaluation in accordance with user selected standards, and generation of a structured report. The user controls these functions with a system of interactive menus and semi-automated or manual workflow automation tools, including: • Manual annotation tools for users to select regions of interest (ROIs), • Semi-automatic lesion segmentation suggestions for user-selected ROIs, • Automatic measurement and display of long and short axis of segmented lesions, • Automatic tabulation and summation of measurements, • Semi-automatic lesion labelling suggestions for anatomical location (organ, body region, and laterality), • Automatic calculation of quantitative and qualitative metrics using annotation data in accordance with the selected criteria, and • Automatic generation of a structured report that includes the annotation data and calculated quantitative and qualitative metrics presented in a graph, table, key images, and structured text report. FDA UDI
Identifiers
- Catalog Number
- AIM1 FDA UDI
- Primary DI / UDI-DI
- G090AIM11 FDA UDI
- 510(k) Number
- K202229 FDA UDI
- FDA Product Code
- LLZ FDA UDI
- GMDN Term
- Radiological PACS software FDA UDI
Classification
- Device Class
- Class II FDA UDI
- Regulation Number
- 892.2050 FDA UDI
- Commercial Distribution
- In Commercial Distribution FDA UDI
Clinical & Handling
Sterile
No
FDA UDI
Single Use
No
FDA UDI
Implantable
No
FDA UDI
Contains Latex
No
FDA UDI
Prescription Use
No
FDA UDI
Over-the-Counter
No
FDA UDI
Convenience Kit
No
FDA UDI
Combination Product
No
FDA UDI
HCT/P
No
FDA UDI
Premarket Exempt
No
FDA UDI
Lot / Batch Number
Yes
FDA UDI
Serial Number
No
FDA UDI
Expiration Date
No
FDA UDI
Manufacturing Date
Yes
FDA UDI
Category: Radiological PACS software
AI Metrics by Ai Metrics, LLC — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS
Similar devices
Also classified as Radiological PACS software.
- AVIEW — CORELINE SOFT CO., LTD. · Class II
- ThinkingNet — THINKING SYSTEMS CORP. · Class II
- IMAGEGRID RADIOLOGY VIEWER SYSTEM — Candelis, Inc. · Class II
- EAGLESOFT — PATTERSON TECHNOLOGY CENTER · Class II
- QuantX — Qlarity Imaging · Class II
- interWORKS — Avreo, Inc. · Class I
- NovaPACS — Novarad Corporation · Class II
- OrthoNext™ Platform System Software — Orthofix, Inc. · Class II
Authorization Coverage (1 country)
Regulatory Authorizations
United States Pending data
FDA UDI
| Source | Region | Type | Cert / Approval No. | Class | Status |
|---|---|---|---|---|---|
| FDA UDI | United States | FDA UDI | Registered in GUDID | Class II | Pending data |
Is this your device? Claim it to add documentation and request validation.
Manufacturer
- Manufacturer
- Ai Metrics, LLC
Sources (1)
- FDA UDI ed07570a-ef6b-4c8b-b220-cdba9e424d4e 36 fields · synced Jun 8, 2026