Skip to content

Alethia™ CMV 481325

by Meridian Bioscience Inc.

Ref 481325

Alethia CMV 481325 is an in vitro diagnostic device (EU IVDR Class C; FDA Class II; FDA product code QDZ) made by Meridian Bioscience Inc., registered in EUDAMED on 14 Sep 2026 (Basic UDI-DI 008407331ALETHIACLC002RD) and listed in FDA GUDID since 9 Jan 2019 (UDI-DI 00840733102080), active as of 8 Nov 2026.

Active European Union. Also listed in GUDID (US).

CE IVDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

Not checked

No FDA submission to match recalls against

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 8 Nov 2026.

Regulatory status

as of registry sync 8 Nov 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number008407331ALETHIACLC002RD Basic UDI-DI 00840733102080UDI-DIDate14 Sep 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number00840733102080 UDI-DI Date9 Jan 2019ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
The Alethia CMV Assay Test System includes separately provided test kits for the Alethia CMV DNA Amplification Assay and the Alethia CMV External Control Reagents. The Alethia CMV DNA Amplification Assay, performed on the Alethia instrument, is a qualitative, in vitro diagnostic test system for the direct detection of Cytomegalovirus (CMV) DNA in saliva samples from neonates younger than 21 days of age. The test is used as an aid in the diagnosis of congenital CMV infection. The results of this test should be used in conjunction with the results of other clinical findings. Flocked swabs should be used to collect saliva from neonates. The swab can be collected dry, without viral transport media (VTM), or placed in no more than 1 mL VTM. The Alethia CMV External Control Reagents are used as part of a routine quality control program to aid the user in detection of unexpected conditions that may lead to test errors. The external controls are intended for use with the Alethia CMV DNA Amplification Assay; the controls are not intended for use with other assays or systems.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 8 Nov 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 008407331ALETHIACLC002RD registered 14 Sep 2026 Active
  • FDA GUDID UDI-DI 00840733102080 listed 9 Jan 2019 Listed

Timeline

2 dated events

  1. Listed FDA GUDID 00840733102080
  2. Registered EUDAMED 008407331ALETHIACLC002RD

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Alethia CMV EUDAMED
Alethia™ CMV GUDID
Generic name
Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
Model / Ref / Catalog
481325
Primary DI / UDI-DI
00840733102080
Basic UDI-DI
008407331ALETHIACLC002RD
Direct marketing DI
00840733102080
FDA product code
QDZ
EMDN code
W0105040205 Cmv - na reagents
GMDN term
Cytomegalovirus (CMV) nucleic acid IVD, kit, nucleic acid technique (NAT)
Device class
Class C EUDAMED
Class II GUDID
Regulation number
866.3181
EU registration type
Standard device
EU market of registration
Italy
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Device classEUDAMED
Class C
GUDID
Class II

Device class is stated on each registry's own scale: Class C in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under CMV - NA REAGENTS.

Other devices from Meridian Bioscience Inc.

See all devices from Meridian Bioscience Inc. →

Properties

  • Single use
  • Reagent
  • IVD kit
  • Professional testing
  • Prescription use
  • Convenience kit
  • Lot / batch number
  • Expiration date
Other properties (18, all answered No)