AlignRT Plus OSMS 5.1 - TB 115V
AlignRT Plus OSMS 5.1 - TB 115V is a medical device (FDA Class II; FDA product code IYE, Accelerator, Linear, Medical) made by Vision RT Limited, cleared under FDA 510(k) K123371 on 8 Jan 2013 and listed in FDA GUDID since 23 Sep 2021 (UDI-DI 05056190500153), active as of 22 Oct 2026. 5 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number05056190500153 | Date23 Sep 2021 | StatusListed |
| United States | FDA 510(k) | NumberK123371 | Date8 Jan 2013 | StatusActive |
Official records
- AccessGUDID record 05056190500153
- FDA 510(k) database K123371
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile
Across registries
- FDA 510(k) K123371 decided 8 Jan 2013 Active
- FDA GUDID UDI-DI 05056190500153 listed 23 Sep 2021 Listed
Recalls
-
- Terminated Z-0065-2019
RTInterface error in the event of an I/O error between the IGC PCB and the Framegrabber PCB
-
- Terminated Z-2667-2016
Vision RT Ltd received three (3) reports from different sites that discovered the following issue, unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up for the Optical Surface Monitoring System [OSMS]. 1. CRM 3194, No Serious Injury, No MDR, Aware date: Dec 11, 2015 2. CRM 3321, No Patient Involved, No MDR, Aware date: Jan 19, 2016 3. CRM 4570, No Serious Injury, No MDR, Aware date: March 15, 2016 No patient harm was reported in any of these cases.
-
- Terminated Z-2149-2016
- Terminated Z-2150-2016
Varian Medical Systems has received reports that unintended changes were made to planned couch parameters, specifically the couch rotation parameter, during patient set-up. This can occur when a user sets a different couch rotation from the plan couch rotation while performing patient alignment with Optical Surface Monitoring System [OSMS].
-
- Terminated Z-0464-2015
Potential failure of AlignRT to assert interlock.
Timeline
- Cleared FDA 510(k) K123371
- Recall initiated FDA recalls Z-0464-2015
- Recall initiated FDA recalls Z-2149-2016
- Recall initiated FDA recalls Z-2150-2016
- Recall initiated FDA recalls Z-2667-2016
- Recall initiated FDA recalls Z-0065-2019
- Listed FDA GUDID 05056190500153
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- AlignRT Plus
- Generic name
- Radiological video camera patient positioning/tracking system
- Model / reference
- OSMS 5.1 - TB 115V
- Primary DI / UDI-DI
- 05056190500153
- 510(k) Number
- FDA product code
- IYE
- GMDN term
- Radiological video camera patient positioning/tracking system
- Device class
- Class II
- Regulation number
- 892.5050
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code IYE (Accelerator, Linear, Medical).
- CDR Systems Precision Patient Positioning System by CDR Systems Inc
- PVS Model 1.0 by Medcom GmbH
- Smart Segmentation-Knowledge Based Contouring by Varian Medical Systems, Inc
- DESKTOP PRO by Elekta Inc.
- KLARITY MEDICAL R550-CM5 by Klarity Medical Products, LLC
- MHI-TM2000 Linear Accelerator System, VERO, Imavis by Mitsubishi Heavy Industries, Ltd.
- Delta4 Insight by Scandidos AB
- Orfit Industries 32405/10 by Orfit Industries NV
- KLARITY MEDICAL R550-U10T by Klarity Medical Products, LLC
- THERAC 25 by Theratronics, Inc.