# Alinity 03R7001

> Active: European Union. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/alinity-03r7001>
- Manufacturer: [Abbott Laboratories](https://devicerts.com/manufacturers/abbott-laboratories) (United States)
- Device class: Class A (EU IVDR); Class I (US FDA)
- FDA product code: JJE
- EMDN: W0201020102 AUTOMATED IMMUNOCHEMISTRY ANALYSERS - MODERATE ROUTINE (Throughput \> 100 and \<= 250 test/h)
- GMDN: Chemiluminescent immunoassay analyser IVD (56701)

## Registrations and authorizations

- **EUDAMED** · CE/IVDR · European Union · Basic UDI-DI 038074MPR0370VN · UDI-DI 00380740137410 · registered 2026-11-02 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 00380740137410 · listed 2018-05-31 · status: Listed (GUDID: in commercial distribution)

## Recalls

- Z-0961-2026 · Class II · ongoing · initiated 2025-11-13: Abbott Laboratories is recalling their Alinity ci-series System Control Module, a chemistry/immunoassay anayzer, by correction. The reason for the recall is potential performance issues found in the Alinity ci-series System software versions 3.6.1. and lower that could lead to erroneous results for multiple analytes. The issue was identified by Abbott during the internal testing of complaint investigations.
- Z-0613-2024 · Class II · ongoing · initiated 2023-05-30: There are potential performance issues found in the Alinity ci-series System software versions 3.4.0 and lower, including: 1) SCC Reagent load error during daily maintenance; 2) Sample Laboratory Report error; 3) Customer requests mechanism to prevent user error when creating new lots of value assigned Calibrators; 4) Error in processing tests after CCCintController encountered an error with the assay information downloaded from SCC; 5) The assay editor does not correctly check sample dilution total volume limits; 6) User-Applied Labels not adhering to Reagent Bottles; 7) ICT Module did not expire after warranty was exceeded. These performance issues could lead to erroneous results for multiple analytes.

## Identity

- Trade name: Alinity [EUDAMED, FDA GUDID (AccessGUDID)]
- Generic name: Chemiluminescent immunoassay analyser IVD [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: 03R7001 [EUDAMED, FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 00380740137410 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 038074MPR0370VN [EUDAMED]
- FDA product code: JJE [FDA GUDID (AccessGUDID)]
- EMDN code: W0201020102 [EUDAMED]
- GMDN term: Chemiluminescent immunoassay analyser IVD (56701) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class A [EUDAMED]; Class I [FDA GUDID (AccessGUDID)]
- Regulation number: 862.2160 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Germany [EUDAMED]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Professional testing: Yes [EUDAMED]
- IVD instrument: Yes [EUDAMED]
- Serial number: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains substances of microbial origin: No [EUDAMED]
- Reagent: No [EUDAMED]
- IVD kit: No [EUDAMED]
- Self-testing: No [EUDAMED]
- Near-patient testing: No [EUDAMED]
- Companion diagnostics: No [EUDAMED]
- New device: No [EUDAMED]
- Prescription use: No [FDA GUDID (AccessGUDID)]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Lot / batch number: No [FDA GUDID (AccessGUDID)]
- Expiration date: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Alinity 03R7001, Abbott Laboratories. deviCERTS medical device catalogue. https://devicerts.com/devices/alinity-03r7001 (data as of 2026-11-23).
- Data sources: [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed), [FDA recalls](https://open.fda.gov/apis/device/recall/)
- Registry records last synced: 2026-11-07
- Statuses computed as of: 2026-11-23
- JSON: <https://devicerts.com/devices/alinity-03r7001.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/alinity-03r7001
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.