Alternanas Processing System, Ch 2000 Cardiac Diagnostic System, Heartwave Alternans Processing System
510(k) K012206
Active
Valid until
No expiry
FDA recalls
None foundDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK012206 | Date12 Oct 2001 | StatusActive |
Recalls
No FDA recalls found in the data synced 22 Oct 2026.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- DQK
- Device Class
- Class II
- Regulation
- 21 CFR Part 870.1425
- Advisory Committee
- Cardiovascular
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 26 Sep 2026
The Alternans Processing System adds T-wave alternans diagnostic capabilities to standard stress test systems and ECG recording devices. It is embodied in two legally marketed products: the Model CH2000 Cardiac Diagnostic System and the Heartwave Alternans Processing System. This system enables the measurement and recording of T-Wave alternans at rest and during treadmill, ergometer, electrophysiological, and pharmacologic stress testing.
The system is intended for use with computer-based ECG systems that include the feature for T-Wave alternans measurement. It is supplied as a diagnostic system with specific model numbers and reference codes. The device received FDA 510(k) clearance with the K number K012206 and product code DQK, classified under the Cardiovascular advisory committee.
Other devices from Cambridge Heart, Inc.
Questions
AI-generated answers, 26 Sep 2026
What is the Alternans Processing System used for?
The Alternans Processing System adds T-wave alternans diagnostic capabilities to standard stress test systems and ECG recording devices, enabling measurement and recording of T-Wave alternans at rest and during various stress testing methods.
How is the Alternans Processing System supplied?
The system is supplied as a diagnostic system with specific model numbers and reference codes, embodied in two legally marketed products: the Model CH2000 Cardiac Diagnostic System and the Heartwave Alternans Processing System.
What regulatory approvals does the Alternans Processing System have?
The device received FDA 510(k) clearance with K number K012206 and product code DQK, classified under the Cardiovascular advisory committee, with a decision date of 2001-10-12.
What types of stress testing can be performed with this system?
The system enables measurement and recording of T-Wave alternans during treadmill, ergometer, electrophysiological, and pharmacologic stress testing, as well as at rest.