← Back to catalogue

Anovo Surgeon Console

FDA UDI

Class II (US FDA UDI)

by Momentis Surgical Ltd

Identity

Trade Name
Anovo Surgeon Console FDA UDI
Generic Name
Endoscopic electromechanical surgical system FDA UDI
Device Name
The Anovo Surgical System is a robotic-assisted device intended for use by laparoscopic trained physicians for endoscopic manipulation of tissue, using graspers and electrosurgery devices during single-site laparoscopic procedures. The system composed of Anovo Surgeon Console, two sterile instruments (Anovo Instrument ARMS), Robotic Control Unit (RCU) and Anovo System Accessories (Unit cables, Sterile Drapes, Pedestal, and Vaginal Access Kit). The Surgeon Console is the main Human Machine Interface (HMI) for the Anovo Surgical System and provides complete control over the Instrument ARMS through the RCU, by manipulating the ARMS Controllers and Flex Controls. It is located in the non-sterile area of the Operating Room. FDA UDI
Model / Reference
20 FDA UDI
Description
The Anovo Surgical System is a robotic-assisted device intended for use by laparoscopic trained physicians for endoscopic manipulation of tissue, using graspers and electrosurgery devices during single-site laparoscopic procedures. The system composed of Anovo Surgeon Console, two sterile instruments (Anovo Instrument ARMS), Robotic Control Unit (RCU) and Anovo System Accessories (Unit cables, Sterile Drapes, Pedestal, and Vaginal Access Kit). The Surgeon Console is the main Human Machine Interface (HMI) for the Anovo Surgical System and provides complete control over the Instrument ARMS through the RCU, by manipulating the ARMS Controllers and Flex Controls. It is located in the non-sterile area of the Operating Room. FDA UDI

Identifiers

Catalog Number
FP-03-0003 FDA UDI
Primary DI / UDI-DI
07290018151303 FDA UDI
FDA Product Code
QNM FDA UDI
GMDN Term
Endoscopic electromechanical surgical system FDA UDI

Classification

Device Class
Class II FDA UDI
Regulation Number
878.4961 FDA UDI
Commercial Distribution
In Commercial Distribution FDA UDI

Clinical & Handling

Sterile

No

FDA UDI

Single Use

No

FDA UDI

Implantable

No

FDA UDI

Contains Latex

No

FDA UDI

Prescription Use

Yes

FDA UDI

Over-the-Counter

No

FDA UDI

Convenience Kit

No

FDA UDI

Combination Product

No

FDA UDI

HCT/P

No

FDA UDI

Premarket Exempt

No

FDA UDI

Lot / Batch Number

No

FDA UDI

Serial Number

Yes

FDA UDI

Expiration Date

No

FDA UDI

Manufacturing Date

Yes

FDA UDI

Category: Endoscopic electromechanical surgical system

Anovo Surgeon Console by Momentis Surgical Ltd — Class II — FDA UDI — listed in FDA GUDID — regulatory data on deviCERTS

Similar devices

Also classified as Endoscopic electromechanical surgical system.

Authorization Coverage (1 country)

Regulatory Authorizations

United States Pending data

FDA UDI

Is this your device? Claim it to add documentation and request validation.

Manufacturer

Sources (1)

  • FDA UDI d326555e-327d-40fb-9b08-bf32d1511222 34 fields · synced May 30, 2026