Anterion Software V. 1.5
by Heidelberg Engineering GmbH Germany EUDAMED510(k)
Ref 4001670Model ANTERION Software V. 1.5
EMDN Z12120192
Overview
Anterion Software V. 1.5 is a diagnostic imaging device classified as Optical Coherence Tomography (OCT) for ophthalmic use, specialising in anterior segment imaging. It provides detailed visualisation and measurement of corneal topography, anterior chamber dimensions, lens structure, and axial length, supporting comprehensive ocular assessments.
The software is designed for single-use in clinical settings, including ophthalmology practices and surgical planning environments. Supplied as a non-sterile, non-reusable digital platform, it operates without MRI restrictions and requires no reprocessing. Authorised under FDA 510K and MDR compliance, it integrates seamlessly into workflows for corneal tomography, biometry, and intraocular lens (IOL) calculations, adhering to regulatory standards for diagnostic imaging devices.
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number4059237ANTERION_SWZ8 | Date28 Mar 2025 | StatusActive |
| United States | FDA 510(k) 510(k) | NumberK240924 | Date13 Dec 2024 | StatusActive |
Coverage
- Active
- Not covered
- United States
- European Union
Specification
- Full name
- ANTERION Software
- Model / Reference
- ANTERION Software V. 1.5, 4001670
- Primary DI / UDI-DI
- 04059237000907
- Basic UDI-DI
- 4059237ANTERION_SWZ8
- Direct Marketing DI
- 04059237000907
- EMDN Code
- Z12120192 Ophtalmology assessments and diagnosis instruments - medical device software
- Device Class
- Class IIb
- Special Device Type
- Software
- Market of Registration
- Germany
Manufacturer details
- EUDAMED SRN
- DE-MF-000008127
Other devices from Heidelberg Engineering GmbH
Questions
What clinical applications does the ANTERION Software support in ophthalmology?
The ANTERION Software V. 1.5 specializes in anterior segment imaging using Optical Coherence Tomography (OCT) to provide detailed visualization and measurements of corneal topography, anterior chamber dimensions, lens structure, and axial length. These capabilities support comprehensive ocular assessments, including corneal tomography, biometry, and intraocular lens (IOL) calculations, making it useful for surgical planning and routine ophthalmic evaluations.
Is the ANTERION Software reusable or single-use, and what does that mean for clinical workflows?
The ANTERION Software is designed for single-use in clinical settings, meaning each installation or session is intended for one patient evaluation. Since it is a non-sterile, non-reusable digital platform, there is no need for reprocessing or sterilization between uses, simplifying workflows and reducing administrative burdens. Clinicians can rely on consistent performance without concerns about contamination or degradation over multiple uses.
How is the ANTERION Software supplied, and are there any special handling requirements?
The ANTERION Software is supplied as a non-sterile digital platform and does not require physical reprocessing or sterilization. It operates independently of hardware sterilization constraints, meaning it can be used directly after installation without additional preparation. However, since it is a software-based solution, ensure the underlying hardware (e.g., OCT scanner) meets the manufacturer’s operational and environmental requirements, such as temperature and humidity controls for optimal performance.
What regulatory pathways does the ANTERION Software follow, and how does that affect its use?
The ANTERION Software has been authorized through FDA 510K clearance and MDR compliance, confirming it meets regulatory standards for diagnostic imaging devices in the U.S. and EU markets. This classification ensures it adheres to safety and performance requirements for optical coherence tomography systems, particularly for anterior segment imaging. Clinicians can rely on its regulatory backing for use in ophthalmic practices, surgical planning, and biometry assessments without additional scrutiny beyond standard software updates or hardware compatibility checks.
Does the ANTERION Software have any restrictions on use with other medical devices or imaging modalities?
The ANTERION Software operates as a standalone diagnostic tool and does not have MRI restrictions, meaning it can be used in environments where MRI-compatible equipment is present. However, its functionality depends on integration with compatible OCT hardware (e.g., Heidelberg Engineering’s scanning systems). Always verify compatibility with the specific hardware model and follow the manufacturer’s guidelines for optimal performance and data accuracy, particularly when combining it with other imaging modalities or devices in clinical workflows.
Properties & raw data
Show properties, registry sources and raw records
Other properties (12)
- Sterile: No
- Implantable: No
- Reusable: No
- Contains Latex: No
- Reprocessed: No
- CMR Substance: No
- Human-derived: No
- Human Tissues: No
- Animal Tissues: No
- Endocrine Disruptor: No
- Administering Medicine: No
- Incorporates Medicinal Product: No
Sources (2)
- EUDAMED 42f3e69c-9b22-479c-8bf0-3f97c55edaa6