Skip to content

Anterior Cervical Plate System

by Encore Orthopedics, Inc.

510(k) K001847

Active United States

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None found

in data synced 22 Oct 2026

Documents

Trust

Unverified

Registry data, not yet checked by deviCERTS. Source FDA 510(k), synced 22 Oct 2026. What this means

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesFDA 510(k)SESE Substantially Equivalent · Traditional NumberK001847 Date24 Aug 2000ClearedStatusActive

Recalls

0 recalls · FDA

No FDA recalls found in the data synced 22 Oct 2026.

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

510(k)

510(k) Number
FDA Product Code
KWQ
Device Class
Class II
Regulation
21 CFR Part 888.3060
Advisory Committee
Orthopedic
FDA Decision
SESE Substantially Equivalent

Overview

AI-generated summary, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

The Anterior Cervical Plate System is a spinal intervertebral body fixation orthosis, classified under FDA regulation 888.3060. It is an implantable device made primarily of titanium, designed to stabilize the cervical spine by securing vertebral plates to adjacent vertebral bodies. The system includes punched plates and eye-type screws to facilitate fixation, with a braided cable for additional support.

This device is intended for surgical use in spinal fixation procedures, providing internal support to the cervical spine. It is supplied sterile and intended for single-use, adhering to FDA 510(k) clearance (K001847) under the Orthopedic Advisory Committee. The system is not MRI-safe and must be handled and stored according to manufacturer guidelines to maintain sterility and integrity.

Other devices from Encore Orthopedics, Inc.

See all devices from Encore Orthopedics, Inc. →

Questions

AI-generated answers, 1 Oct 2026

Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data above is the record.

  • What is the Anterior Cervical Plate System used for?

    The Anterior Cervical Plate System is designed for surgical spinal fixation in the cervical spine. It provides internal support by securing titanium plates to adjacent vertebral bodies, helping stabilize the spine during procedures like fusion or trauma repair. The system includes punched plates, eye-type screws, and a braided cable for enhanced fixation, ensuring proper alignment and immobilization of the cervical vertebrae.

  • Is the Anterior Cervical Plate System reusable or single-use?

    This system is intended for single-use only. It is supplied sterile to ensure patient safety and prevent contamination. Reuse could compromise sterility and integrity, potentially leading to infection or device failure. Always follow manufacturer guidelines for handling and disposal after a single surgical procedure.

  • What materials is the Anterior Cervical Plate System made from?

    The system is primarily constructed from titanium, a biocompatible material known for its strength and corrosion resistance. Titanium is commonly used in spinal implants due to its ability to integrate well with bone tissue while maintaining structural stability. The punched plates, screws, and braided cable are all designed to work together for secure fixation.

  • How should the Anterior Cervical Plate System be stored?

    To maintain sterility and integrity, the system must be stored according to the manufacturer’s instructions. Typically, this involves keeping it in its original packaging in a clean, dry environment away from direct sunlight or extreme temperatures. Avoid opening the sterile barrier until immediately before use, and ensure the packaging remains uncompromised to prevent contamination.

  • Can the Anterior Cervical Plate System be used with MRI imaging?

    No, the Anterior Cervical Plate System is not MRI-safe. The presence of metallic components, such as titanium plates and screws, can interfere with MRI scans and pose risks to patients and equipment. Always confirm imaging compatibility with radiology staff before scheduling any MRI procedures involving this device.