# Aptima CV/TV Assay

> Active: European Union and United States. Medical device record on deviCERTS, compiled from public registries.

- Canonical page: <https://devicerts.com/devices/aptima-cv-tv-assay-pqa>
- Manufacturer: [Hologic, Inc.](https://devicerts.com/manufacturers/hologic-inc) (United States)
- Device class: Class C (EU IVDR); Class II (US FDA)
- FDA product code: PQA, NSU
- EMDN: W0105070501 STIS / STDS (C.TRACHOMATIS, N.GONORRHOEAE ,M.GENITALIUM, T.VAGINALIS, UREAPLASMA SPP….) COMBINATION - MULTIPLEX NA REAGENTS
- GMDN: Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, kit, nucleic acid technique (NAT) (48208)

## Overview

*AI-generated summary, 2026-09-18. Written by a language model from registry data. Not verified by deviCERTS or the manufacturer. The registry data is the record.*

The Aptima CV/TV Assay is a Vaginitis and Bacterial Vaginosis Nucleic Acid Detection System, designed for the molecular detection of \*Chlamydia trachomatis\* (CT) and \*Trichomonas vaginalis\* (TV) in clinical specimens. It employs nucleic acid amplification technology to identify these pathogens, aiding in the diagnosis of sexually transmitted infections and bacterial vaginosis.

This in vitro diagnostic device is intended for laboratory use and is supplied as a single-use reagent kit. It requires no additional sterilisation beyond its pre-packaged, sterile components and is classified as a Class II medical device under FDA regulations. The assay is authorised for use in microbiology settings and complies with both FDA 510(k) clearance and EU IVDR requirements. Storage conditions are specified in the accompanying instructions for use.

## Registrations and authorizations

- **EUDAMED** · CE/IVDR · European Union · Basic UDI-DI 54200455DIAGAPTCVTV2E · UDI-DI 15420045512061 · registered 2026-05-22 · status: Active
- **GUDID** · GUDID listing · United States · UDI-DI 15420045512061 · listed 2019-07-02 · status: Listed (GUDID: in commercial distribution)
- **510(k)** · FDA 510(k) · United States · K190472 · decision 2019-05-16 · decision SESE · status: Active

## Recalls

No recall on record.

## Identity

- Trade name: Aptima CV/TV Assay [EUDAMED]; Aptima® [FDA GUDID (AccessGUDID)]
- Generic name: Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, kit, nucleic acid technique (NAT) [FDA GUDID (AccessGUDID)]
- Model / Ref / Catalog: PRD-05189 [EUDAMED]; KIT [FDA GUDID (AccessGUDID)]; BOX 1 [FDA GUDID (AccessGUDID)]; REFRIGERATED [FDA GUDID (AccessGUDID)]; ACV/TV [FDA GUDID (AccessGUDID)]; 100T [FDA GUDID (AccessGUDID)]; IVD [FDA GUDID (AccessGUDID)]; ASY-11569 [FDA GUDID (AccessGUDID)]

## Identifiers

- Primary DI / UDI-DI: 15420045512061 [EUDAMED, FDA GUDID (AccessGUDID)]
- Basic UDI-DI: 54200455DIAGAPTCVTV2E [EUDAMED]
- Direct marketing DI: 15420045512061 [EUDAMED]
- 510(k) Number: K190472 [FDA 510(k), FDA GUDID (AccessGUDID)]
- FDA product code: PQA [FDA 510(k), FDA GUDID (AccessGUDID)]; NSU [FDA GUDID (AccessGUDID)]
- EMDN code: W0105070501 [EUDAMED]
- GMDN term: Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, kit, nucleic acid technique (NAT) (48208) [FDA GUDID (AccessGUDID)]

## Classification

- Device class: Class C [EUDAMED]; Class II [FDA 510(k), FDA GUDID (AccessGUDID)]
- Regulation: 21 CFR Part 866.3975 [FDA 510(k), FDA GUDID (AccessGUDID)]; 862.2570 [FDA GUDID (AccessGUDID)]
- EU registration type: Standard device [EUDAMED]
- EU market of registration: Belgium [EUDAMED]
- Advisory committee: Microbiology [FDA 510(k)]
- FDA decision: SESE [FDA 510(k)]
- GUDID distribution status: In Commercial Distribution [FDA GUDID (AccessGUDID)]

## Properties

- Reagent: Yes [EUDAMED]
- IVD kit: Yes [EUDAMED]
- Professional testing: Yes [EUDAMED]
- Prescription use: Yes [FDA GUDID (AccessGUDID)]
- Lot / batch number: Yes [FDA GUDID (AccessGUDID)]
- Expiration date: Yes [FDA GUDID (AccessGUDID)]
- Supplied sterile: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Sterilise before use: No [EUDAMED, FDA GUDID (AccessGUDID)]
- Single use: No [FDA GUDID (AccessGUDID)]
- Implantable: No [FDA GUDID (AccessGUDID)]
- Contains latex: No [FDA GUDID (AccessGUDID)]
- Contains human tissues or cells: No [EUDAMED]
- Contains animal tissues or cells: No [EUDAMED]
- Contains substances of microbial origin: No [EUDAMED]
- Self-testing: No [EUDAMED]
- Near-patient testing: No [EUDAMED]
- Companion diagnostics: No [EUDAMED]
- IVD instrument: No [EUDAMED]
- New device: No [EUDAMED]
- Over-the-counter: No [FDA GUDID (AccessGUDID)]
- Convenience kit: No [FDA GUDID (AccessGUDID)]
- Combination product: No [FDA GUDID (AccessGUDID)]
- HCT/P: No [FDA GUDID (AccessGUDID)]
- Premarket exempt: No [FDA GUDID (AccessGUDID)]
- Serial number: No [FDA GUDID (AccessGUDID)]
- Manufacturing date: No [FDA GUDID (AccessGUDID)]

## Source and citation

- Cite as: Aptima CV/TV Assay, Hologic, Inc. deviCERTS medical device catalogue. https://devicerts.com/devices/aptima-cv-tv-assay-pqa (data as of 2026-11-20).
- Data sources: [FDA 510(k)](https://open.fda.gov/apis/device/510k/), [FDA GUDID (AccessGUDID)](https://accessgudid.nlm.nih.gov/), [EUDAMED](https://ec.europa.eu/tools/eudamed)
- Registry records last synced: 2026-10-22
- Statuses computed as of: 2026-11-20
- JSON: <https://devicerts.com/devices/aptima-cv-tv-assay-pqa.json>
- Licence: [CC BY 4.0](https://creativecommons.org/licenses/by/4.0/). The deviCERTS layout and text are licensed under CC BY 4.0. Registry data remain under their source terms: U.S. FDA data (openFDA, AccessGUDID) are U.S. public domain; EUDAMED data are subject to the European Commission reuse terms.
- Attribution: DevicErts, https://devicerts.com/devices/aptima-cv-tv-assay-pqa
- Compiled by deviCERTS (devicerts.com) from public medical device registries (EUDAMED, European Commission; U.S. FDA via openFDA; AccessGUDID, U.S. National Library of Medicine). deviCERTS is not an official register and gives no regulatory advice: the record in the registry itself prevails.