Skip to content

Aptima®

by Hologic 5 variants

Part of a family of 6 devices: see the family page

Ref PRD-07665

Aptima (ASY-16708) is an in vitro diagnostic device (EU IVDR Class C; FDA Class II; EMDN category stis / stds (c.trachomatis) made by Hologic, registered in EUDAMED on 22 May 2026 (Basic UDI-DI 54200455DIAGAPTCVTV2E), cleared under FDA 510(k) K243345 on 25 Nov 2024 and listed in FDA GUDID since 19 Dec 2024 (UDI-DI 15420045517073), active as of 24 Oct 2026.

Active European Union and United States. Also listed in GUDID (US).

CE IVDR 510(k)

Valid until

No date given

CE: no date in EUDAMED. FDA: not time-limited

FDA recalls

None found

in data synced 24 Oct 2026

Documents

None linked in EUDAMED

A group certificate may exist

510(k) K243345

FDA submission, from GUDID

Trust

Unverified

Source EUDAMED, GUDID, synced 24 Oct 2026.

Regulatory status

as of registry sync 24 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/IVDR EUDAMED Number54200455DIAGAPTCVTV2E Basic UDI-DI 15420045517073UDI-DIDate22 May 2026RegisteredStatusActive
United StatesGUDID listing GUDID Number15420045517073 UDI-DI Date19 Dec 2024ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE GUDID from GUDID Substantially Equivalent · Special NumberK243345 Date25 Nov 2024DecidedStatusActive

Official records

From the FDA record

Device description
Aptima® CV/TV assay, 250 test, box 1 of 2 (2°C to 8°C box). The Aptima® CV/TV assay is an in vitro nucleic acid amplification test for the detection of RNA from microorganisms associated with vulvovaginal candidiasis and trichomoniasis.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 24 Oct 2026, as the labeller entered it.

Across registries

3 registries list this device

  • EUDAMED Basic UDI-DI 54200455DIAGAPTCVTV2E registered 22 May 2026 Active
  • FDA 510(k) K243345 decided 25 Nov 2024 Active
  • FDA GUDID UDI-DI 15420045517073 listed 19 Dec 2024 Listed

Timeline

3 dated events

  1. Cleared FDA 510(k) K243345
  2. Listed FDA GUDID 15420045517073
  3. Registered EUDAMED 54200455DIAGAPTCVTV2E

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/IVDR Active
  • United States FDA 510(k) Active

Specification

EUDAMED · GUDID

Trade name
Aptima CV/TV Assay EUDAMED
Aptima® GUDID
Generic name
Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, kit, nucleic acid technique (NAT)
Model / Ref / Catalog
PRD-07665 EUDAMED
KIT GUDID
BOX 1 GUDID
REFRIGERATED GUDID
ACV/TV GUDID
250T GUDID
IVD GUDID
ASY-16708 GUDID
Primary DI / UDI-DI
15420045517073
Basic UDI-DI
54200455DIAGAPTCVTV2E
Direct marketing DI
15420045517073
510(k) Number
FDA product code
NSU, PQA
EMDN code
W0105070501 Stis / stds (c.trachomatis, n.gonorrhoeae ,m.genitalium, t.vaginalis, ureaplasma spp….) combination - multiplex na reagents
GMDN term
Multiple vaginitis/vaginosis-associated pathogen nucleic acid IVD, kit, nucleic acid technique (NAT)
Device class
Class C EUDAMED
Class II GUDID
Regulation number
862.2570, 866.3975
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 2 fields differ

FieldEUDAMEDGUDID
Model / referenceEUDAMED
PRD-07665
GUDID
KIT, BOX 1, REFRIGERATED, ACV/TV, 250T, IVD
Device classEUDAMED
Class C
GUDID
Class II

Device class is stated on each registry's own scale: Class C in the EU (EUDAMED), Class II in the US (FDA GUDID). EU and US classes are different schemes, so this is not a disagreement.

Similar devices in this category

Other devices filed under STIS / STDS (C.TRACHOMATIS, N.GONORRHOEAE ,M.GENITALIUM, T.VAGINALIS, UREAPLASMA SPP….) COMBINATION - MULTIPLEX NA REAGENTS.

Other devices from Hologic

See all devices from Hologic →

Properties

  • Reagent
  • IVD kit
  • Professional testing
  • Prescription use
  • Lot / batch number
  • Expiration date
Other properties (20, all answered No)