2.0/2.3 Grid Fix.Pl 3x2 Hole Rect., t1.0
by Medartis AG
Part of a family of 1,049 devices: see the family page
Ref A-4600.55
2.0/2.3 Grid Fix.Pl 3x2 Hole Rect., t1.0 (A-4600.55) is an orthopaedic fixation plate (EU MDR Class IIb; FDA Class II; FDA product code HRS, Plate, fixation, bone) made by Medartis AG, registered in EUDAMED on 25 Mar 2025 (Basic UDI-DI 76300378020P6), cleared under FDA 510(k) K051567 on 23 Aug 2005 and listed in FDA GUDID since 24 Feb 2023 (UDI-DI 07630037863403), active as of 22 Oct 2026.
Active
CE MDR 510(k)
Valid until
No date given
FDA recalls
1 ongoingTrust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| European Union | CE/MDR EUDAMED | Number76300378020P6 07630037863403 | Date25 Mar 2025 | StatusActive |
| United States | GUDID listing GUDID | Number07630037863403 | Date24 Feb 2023 | StatusListed |
| United States | FDA 510(k)SESE GUDID | NumberK051567 | Date23 Aug 2005 | StatusActive |
Official records
- EUDAMED public site 76300378020P6
- AccessGUDID record 07630037863403
- FDA 510(k) database K051567
From the FDA record
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied non-sterile; sterilise before use (Moist Heat or Steam Sterilization)
Across registries
- EUDAMED Basic UDI-DI 76300378020P6 registered 25 Mar 2025 Active
- FDA 510(k) K051567 decided 23 Aug 2005 Active
- FDA GUDID UDI-DI 07630037863403 listed 24 Feb 2023 Listed
Recalls
-
- Ongoing Z-1549-2026
Mix up between specified lots of 2.5mm and 2.8mm outer diameter screws.
Timeline
- Cleared FDA 510(k) K051567
- Listed FDA GUDID 07630037863403
- Registered EUDAMED 76300378020P6
- Recall initiated FDA recalls Z-1549-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
- European Union
- United States
Specification
- Trade name
- 2.0/2.3 Grid Fix.Pl 3x2 Hole Rect., t1.0 EUDAMEDAptus GUDID
- Generic name
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
- Device name
- Bone plates (sterile, non-sterile)
- Model / Ref / Catalog
- A-4600.55
- Primary DI / UDI-DI
- 07630037863403
- Basic UDI-DI
- 76300378020P6
- 510(k) Number
- FDA product code
- HRS
- EMDN code
- P09120599 Bone fixation plates - other
- GMDN term
- Orthopaedic fixation plate, non-bioabsorbable, non-sterile
- Device class
- Class IIb EUDAMEDClass II GUDID
- Regulation number
- 888.3030
- EU registration type
- Standard device
- EU market of registration
- Germany
- GUDID distribution status
- In Commercial Distribution
- Sterilisation method
- Moist Heat or Steam Sterilization
Truth per registry
| Field | EUDAMED | GUDID |
|---|---|---|
| Device class | Class IIb | Class II |
| Implantable | Yes | No |
Manufacturer details
- EUDAMED SRN
- CH-MF-000022291
- Authorised representative
- Medartis GmbH DE-AR-000005810
Similar devices in this category
Other devices filed under BONE FIXATION PLATES - OTHER.
- Sorath, Sorath Ortho A17201035 by Sigma Surgical Private Limited
- Leforte System Bone Plate 242.80AE04 by Jeil Medical Corporation
- Cable-Ready® Cable Grip System, Greater Trochanteric Reattachment (GTR) Device 401-084 2232-02-06 by Pioneer Surgical Technology Inc.
- ZİMED MEDİKAL SANAYİ VE TİCARET LİMİTED ŞİRKETİ 2932-4018 by Zimed Medikal Sanayi ve Ticaret Limited Şirketi
- LCP Straight Plate 2.4 F14AB-PA00857 by WUHAN MINDRAY SCIENTIFIC CO., LTD.
- HINGE PEDIATRIC PLATING SYSTEM HPI012 by Orthopediatrics Canada ULC
- Leforte System Bone Plate 20-ST-005-R15 by Jeil Medical Corporation
- Piccolo Composite Plate System Lapidus Plate LAP100001 by CARBOFIX ORTHOPEDICS LTD
- Piccolo Composite Plate System One-Third Tubular Plate POTTN2011 by CARBOFIX ORTHOPEDICS LTD
- FLAT WASHER 14460 by Biomet Orthopedics, Inc.