Aquadex FlexFlow System 2.0
510(k) K192756
Active
Valid until
No expiry
FDA recalls
None ongoingDocuments
Trust
Unverified
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | FDA 510(k)SESE | NumberK192756 | Date24 Feb 2020 | StatusActive |
Recalls
-
- Completed Z-0831-2025
The AquaFlexFlow UF 500 Plus extracorporeal blood circuit used with the Aquadex SmartFlow and FlexFlow Systems may indicate "Ultrafiltrate Weight Mismatch" or Excessive Weight Mismatch Alarms while in use. If not addressed, this failure could result in excess fluid removal from a patient leading to Acute Volume Depletion. This failure is especially serious when the Aquadex System is being used on pediatric patients.
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- 510(k) Number
- FDA Product Code
- KDI
- Device Class
- Class II
- Regulation
- 21 CFR Part 876.5860
- Advisory Committee
- Gastroenterology, Urology
- FDA Decision
- SESE Substantially Equivalent
Overview
AI-generated summary, 1 Oct 2026
The Aquadex FlexFlow System 2.0 is a high-permeability hemodialysis device designed for continuous ultrafiltration therapy. It facilitates the removal of excess fluid and solutes from the bloodstream in adult and pediatric patients weighing 20 kilograms or more, supporting temporary (up to 8 hours) or extended (longer than 8 hours) use in hospitalized patients. The system is intended for patients requiring hospitalization due to fluid overload or other conditions necessitating controlled ultrafiltration.
The device is supplied as a single-use, sterile system and is classified under 21 CFR 876.5860 as a Class II medical device with product code KDI. It is intended for use in clinical settings where ultrafiltration therapy is administered, adhering to regulatory standards for hemodialysis systems. The system’s design and components are optimized for compatibility with standard hemodialysis protocols, ensuring safe and effective fluid management in patients requiring such interventions.
Other devices from Chf Solutions, Inc.
Questions
AI-generated answers, 1 Oct 2026
What is the Aquadex FlexFlow System 2.0 used for?
The Aquadex FlexFlow System 2.0 is designed for continuous ultrafiltration therapy, specifically to remove excess fluid and solutes from the bloodstream. It is intended for hospitalized patients weighing 20 kilograms or more who require controlled ultrafiltration due to fluid overload or other conditions necessitating temporary (up to 8 hours) or extended (longer than 8 hours) ultrafiltration support.
Is the Aquadex FlexFlow System 2.0 single-use or reusable?
The Aquadex FlexFlow System 2.0 is supplied as a single-use, sterile device. This design ensures patient safety by preventing cross-contamination and maintaining sterility between uses, which is critical in clinical settings where ultrafiltration therapy is administered.
What are the key specifications or classifications for this device?
The Aquadex FlexFlow System 2.0 is classified under 21 CFR 876.5860 as a Class II medical device with the product code KDI. It is intended for use in clinical settings where hemodialysis protocols are followed, ensuring compatibility with standard ultrafiltration therapy practices. The system’s high-permeability design supports efficient fluid management.
How should the Aquadex FlexFlow System 2.0 be stored?
While the provided data does not specify storage conditions explicitly, single-use sterile medical devices like the Aquadex FlexFlow System 2.0 are generally stored in a clean, dry environment protected from direct sunlight, extreme temperatures, and physical damage. Always follow the manufacturer’s instructions for optimal shelf life and sterility preservation.
What regulatory pathway was followed for this device?
The Aquadex FlexFlow System 2.0 underwent a traditional 510(k) clearance process through the FDA, with a decision described as ‘Substantially Equivalent.’ The device was reviewed by the Gastroenterology and Urology (GU) Advisory Committee, and it was determined to be substantially equivalent to a predicate device, ensuring compliance with regulatory standards for hemodialysis systems.