Skip to content

Aquadex SmartFlow Console 120100

by Nuwellis, Inc.

Aquadex SmartFlow Console 120100 is a haemofiltration system (FDA Class II; FDA product code KDI, Dialyzer, High Permeability With Or Without Sealed Dialysate System) made by Nuwellis, Inc., cleared under FDA 510(k) K192756 on 24 Feb 2020 and listed in FDA GUDID since 3 Mar 2020 (UDI-DI 10853072007104), active as of 23 Oct 2026. One FDA recall is linked to it.

Active United States. Also listed in GUDID (US).

510(k)

Valid until

No expiry

510(k) clearance is not time-limited

FDA recalls

None ongoing

1 closed

Documents

510(k) K192756

FDA submission, from GUDID

Trust

Unverified

Source GUDID, synced 23 Oct 2026.

Regulatory status

as of registry sync 23 Oct 2026

RegionAuthorizationNumberDateStatus
United StatesGUDID listing Number10853072007104 UDI-DI Date3 Mar 2020ListedStatusListed GUDID: in commercial distribution
United StatesFDA 510(k)SESE from GUDID Substantially Equivalent · Traditional NumberK192756 Date24 Feb 2020DecidedStatusActive

Official records

From the FDA record

Device description
The Aquadex SmartFlow System is indicated for: Continuous ultrafiltration therapy for temporary (up to 8 hours) or extended (longer than 8 hours in patients who require hospitalization) use in adult and pediatric patients weighing 20 kilograms or more whose fluid overload is unresponsive to medical management, including diuretics. All treatments must be administered within an outpatient or inpatient clinical setting by a healthcare provider, under physician prescription, both of whom having received training in extracorporeal therapies.
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 23 Oct 2026, as the labeller entered it.

Across registries

2 registries list this device

  • FDA 510(k) K192756 decided 24 Feb 2020 Active
  • FDA GUDID UDI-DI 10853072007104 listed 3 Mar 2020 Listed

Recalls

1 recall · FDA

    • Completed Z-0831-2025 FDA Class I initiated 11 Dec 2024

    The AquaFlexFlow UF 500 Plus extracorporeal blood circuit used with the Aquadex SmartFlow and FlexFlow Systems may indicate "Ultrafiltrate Weight Mismatch" or Excessive Weight Mismatch Alarms while in use. If not addressed, this failure could result in excess fluid removal from a patient leading to Acute Volume Depletion. This failure is especially serious when the Aquadex System is being used on pediatric patients.

Timeline

3 dated events

  1. Cleared FDA 510(k) K192756
  2. Listed FDA GUDID 10853072007104
  3. Recall initiated FDA recalls Z-0831-2025

Coverage

1 jurisdiction

United States of America
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered

United States — FDA 510(k) Active

Specification

GUDID

Trade name
Aquadex SmartFlow Console
Generic name
Haemofiltration system
Model / Ref / Catalog
120100
Primary DI / UDI-DI
10853072007104
510(k) Number
FDA product code
KDI
GMDN term
Haemofiltration system
Device class
Class II
Regulation number
876.5860
GUDID distribution status
In Commercial Distribution

Similar devices

Other devices filed under FDA product code KDI (Dialyzer, High Permeability With Or Without Sealed Dialysate System).

Other devices from Nuwellis, Inc.

See all devices from Nuwellis, Inc. →

Properties

  • Prescription use
  • Serial number
Other properties (13, all answered No)