Skip to content

Arlite-R

by mo-vis bv

Part of a family of 10 devices: see the family page

Ref PRSPS00018

Arlite-R (PRSPS00018) is a wheelchair steering/control unit (EU MDR Class I; FDA Class I; FDA product code KNN, Components, Wheelchair) made by mo-vis bv, registered in EUDAMED on 25 Mar 2025 (Basic UDI-DI 540700832ALLRJS4K) and listed in FDA GUDID since 28 Jul 2022 (UDI-DI 05407008320898), active as of 22 Oct 2026. One FDA recall is linked to it.

Active European Union. Also listed in GUDID (US).

CE MDR

Valid until

No date given

EUDAMED holds no validity date

FDA recalls

1 ongoing

Recall lists catalog no. PRSPS00018; version and lot not checked

Documents

None linked in EUDAMED

A group certificate may exist

Trust

Unverified

Source EUDAMED, GUDID, synced 22 Oct 2026.

Regulatory status

as of registry sync 22 Oct 2026

RegionAuthorizationNumberDateStatus
European UnionCE/MDR EUDAMED Number540700832ALLRJS4K Basic UDI-DI 05407008320898UDI-DIDate25 Mar 2025RegisteredStatusActive
United StatesGUDID listing GUDID Number05407008320898 UDI-DI Date28 Jul 2022ListedStatusListed GUDID: in commercial distribution

Official records

From the FDA record

Device description
All-Round Joystick Omni Light
MRI safety
Labeling does not contain MRI Safety Information
Natural rubber latex
No latex statement on the label
Sterility
Supplied non-sterile

From the GUDID record (AccessGUDID), as read on 30 May 2026, as the labeller entered it.

Across registries

2 registries list this device

  • EUDAMED Basic UDI-DI 540700832ALLRJS4K registered 25 Mar 2025 Active
  • FDA GUDID UDI-DI 05407008320898 listed 28 Jul 2022 Listed

Recalls

1 recall · 1 ongoing · FDA

    • Ongoing Z-2459-2025 FDA Class I initiated 10 Jul 2025 catalog no. PRSPS00018 listed

    Devices with firmware versions 2.3 and lower may experience timing variations between software tasks, which could result in skipping the necessary neutral check and the wheelchair producing unintended movement upon power-up when the joystick is out of neutral.

A catalog-number match means the recall lists this device's catalog or model number; the software version and lot are not checked.

Timeline

3 dated events

  1. Listed FDA GUDID 05407008320898
  2. Registered EUDAMED 540700832ALLRJS4K
  3. Recall initiated FDA recalls Z-2459-2025

Coverage

2 jurisdictions

United States of AmericaSwedenFinlandLatviaEstoniaDenmarkLithuaniaIrelandNetherlandsGermanyPolandFranceBelgiumLuxembourgCzech RepublicSlovakiaAustriaHungaryRomaniaSloveniaBulgariaPortugalSpainItalyCroatiaGreeceMaltaCyprus
  • Active
  • Expiring
  • Withdrawn
  • Listed
  • Not covered
  • European Union CE/MDR Active
  • United States GUDID listing Listed

Specification

EUDAMED · GUDID

Trade name
Arlite-R EUDAMED
mo-Vis GUDID
Generic name
Wheelchair steering/control unit
Device name
All-round Joystick
Model / reference
PRSPS00018 EUDAMED
IDM-ARLITE-R GUDID
Primary DI / UDI-DI
05407008320898
Basic UDI-DI
540700832ALLRJS4K
FDA product code
KNN
EMDN code
Y122403 Wheelchair footrests, supports and controls
GMDN term
Wheelchair steering/control unit
Device class
Class I
Regulation number
890.3920
System or procedure pack
System which is a device in itself
EU registration type
Standard device
EU market of registration
Belgium
GUDID distribution status
In Commercial Distribution

Truth per registry

2 sources · 1 field differs

FieldEUDAMEDGUDID
Model / referenceEUDAMED
PRSPS00018
GUDID
IDM-ARLITE-R

Manufacturer details

EUDAMED SRN
BE-MF-000000729

Similar devices in this category

Other devices filed under WHEELCHAIR FOOTRESTS, SUPPORTS AND CONTROLS.

Other devices from mo-vis bv

See all devices from mo-vis bv →

Properties

  • Premarket exempt
  • Serial number
  • Manufacturing date
Other properties (22, all answered No)