Arrow IPN040102
Arrow IPN040102 (ASK-05000-GFH1) is an epidural anaesthesia set (FDA Class II; FDA product code CAZ, Anesthesia conduction kit) made by Teleflex Incorporated, cleared under FDA 510(k) K801912 on 16 Sep 1980 and listed in FDA GUDID since 16 Sep 2016 (UDI-DI 10801902114010), active as of 23 Oct 2026. 10 FDA recalls are linked to it.
Active
Valid until
No expiry
FDA recalls
1 ongoingDocuments
Trust
Regulatory status
| Region | Authorization | Number | Date | Status |
|---|---|---|---|---|
| United States | GUDID listing | Number10801902114010 | Date16 Sep 2016 | StatusListed |
| United States | FDA 510(k)SESE | NumberK801912 | Date16 Sep 1980 | StatusActive |
Official records
- AccessGUDID record 10801902114010
- FDA 510(k) database K801912
From the FDA record
- Device description
- Epidural Catheterization Kit with TheraCath(R) Catheter
- MRI safety
- Labeling does not contain MRI Safety Information
- Natural rubber latex
- No latex statement on the label
- Sterility
- Supplied sterile
Across registries
- FDA 510(k) K801912 decided 16 Sep 1980 Active
- FDA GUDID UDI-DI 10801902114010 listed 16 Sep 2016 Listed
Recalls
-
- Ongoing Z-2364-2026
Lidocaine, Bupivacaine, and 0.9% sodium chloride, the subject of a supplier recall, were included into kits and sets. The supplier was found to have quality issues and limited reports of drug ineffectiveness, and if sterility of a water-based injectable product is compromised this could lead to serious or life-threatening injuries.
-
- Terminated Z-2803-2020
The lidstock states the incorrect expiration date for the product. This issue could result in use of a device that is expired which could potentially lead to an increased risk of infection or other complications. Sterility, biocompatibility, safety, or efficacy of the kits and their components are not assured beyond the correct expiration date.
-
- Terminated Z-1175-2020
There is the potential for various failures with the LOR (loss of resistance) syringes included in the kits resulting in dural puncture with some also requiring a blood patch.
-
- Terminated Z-1249-2020
- Terminated Z-1251-2020
- Terminated Z-1246-2020
- Terminated Z-1248-2020
- Terminated Z-1247-2020
- Terminated Z-1245-2020
Product lidstock contains the incorrect expiration date for the product
-
- Terminated Z-2012-2018
Product sterility may be compromised due to unsealed packaging.
Timeline
- Recall initiated FDA recalls Z-2012-2018
- Recall initiated FDA recalls Z-1249-2020
- Recall initiated FDA recalls Z-1251-2020
- Recall initiated FDA recalls Z-1246-2020
- Recall initiated FDA recalls Z-1248-2020
- Recall initiated FDA recalls Z-1247-2020
- Recall initiated FDA recalls Z-1245-2020
- Recall initiated FDA recalls Z-1175-2020
- Recall initiated FDA recalls Z-2803-2020
- Recall initiated FDA recalls Z-2364-2026
Coverage
- Active
- Expiring
- Withdrawn
- Listed
- Not covered
United States — FDA 510(k) Active
Specification
- Trade name
- Arrow
- Generic name
- Epidural anaesthesia set, non-medicated
- Model / Ref / Catalog
- IPN040102, ASK-05000-GFH1
- Primary DI / UDI-DI
- 10801902114010
- 510(k) Number
- FDA product code
- CAZ
- GMDN term
- Epidural anaesthesia set, non-medicated
- Device class
- Class II
- Regulation number
- 868.5140
- GUDID distribution status
- In Commercial Distribution
Similar devices
Other devices filed under FDA product code CAZ (Anesthesia conduction kit).
- ARROW FlexBlock Continuous Peripheral Nerve Block Catheter Kit/Set by Teleflex LLC
- CONTINUOUS EPIDURAL ANESTHESIA TRAY by Portex, Ltd.
- BUSSE PLASTIC LOR SYRINGE by BUSSE HOSPITAL DISPOSABLES
- VARIOUS ANESTHETIC KITS OR TRAYS by SPECIALTY MEDICAL PRODUCTS CO.
- Arrow 0.2 Micron Flat Filter, GVS by Arrow International, Inc.
- B-D DURASAFE COMBINED SPINAL EPIDURAL (CSE) TRAY by Bd Becton Dickinson Vacutainer Systems Preanalytic
- MEDSURG EPIDURAL TRAY/19 GAGE OPEN END TUOHY 1012 by Medsurg Industries, Inc.
- PLEXOLONG SETS by Pajunk GmbH
- DURASAFE B-D COMBINED SPINAL EPIDURAL ANESTHESIA by Bd Becton Dickinson Vacutainer Systems Preanalytic
- EPIFUSE CATHETER CONNECTOR, MODEL: 4909E by Smiths Medical Asd, Inc.